Heated Humidifier Feature

The Integrated Heated Humidifier is a feature that may reduce nasal dryness and irritation by adding moisture and
heat to the airflow. This feature can be enabled or disabled by your home care provider.
If the heated humidifier is enabled on your device, press the HEAT
Setting screen will appear flashing, shown below. You can enter this screen from either the standby or operate screen.
Note: If the heated humidifier feature is disabled by the home care provider, nothing will happen when you press
the HEAT button.
You can increase or decrease the humidifier heat settings by pressing the + or – buttons. The possible settings are
from 0 (off) to 5 which is the highest setting. Once you have chosen your desired setting, you can either press the
HEAT button again or just wait a few moments and the new setting will be saved. The screen will then automatically
return to either the standby or operate screen.
Note: This screen will not display if your provider has not enabled the humidifier on your device.

Ramp Feature

You can press the RAMP
The device is equipped with an optional ramp feature that your home care provider can enable or disable. This
feature reduces the air pressure when you are trying to fall asleep and then gradually increases (ramps) the pressure
until your prescription setting is reached, allowing you to fall asleep more comfortably.
If ramp is enabled on your device, after you turn on the airflow, press the RAMP button on the top of the device. You
can use the RAMP button as often as you wish during the night.
Note: If the ramp feature is disabled, nothing will happen when you press the RAMP button.
In order to adjust the Ramp Starting Pressure, press and hold the RAMP
The Ramp Starting Pressure Screen will appear flashing, shown here. It can be entered from either the standby or
operate screen.
You can increase or decrease the ramp starting pressure in 0.5 cm H
The default setting is 4 cm H
have chosen your desired setting, you can either press the RAMP button again or just wait a few moments and the
new setting will be saved. The screen will then automatically return to either the standby or operate screen.
Note: This screen will not display if your provider has not enabled Ramp on your device.
U
M
ser
anUal
Humidifier Setting Screen
button to activate the Ramp feature, if your provider has enabled this feature.
Ramp Starting Pressure Screen
O. You can adjust the setting from 4 cm H
2
button on the top of the device. The Humidifier
button for approximately 3 seconds.
O increments by pressing the + or – buttons.