Guidance and Manufacturer's Declaration - Electromagnetic Immunity – This device is intended for use in the electromagnetic
environment specified below. The user of this device should make sure it is used in such an environment.
i
t
MMUnity
est
Conducted RF
3 Vrms
IEC 61000-4-6
150 kHz to 80 MHz
Radiated RF
3 V/m
IEC 61000-4-3
80 MHz to 2.5 GHz
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects,
and people.
a
Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM
and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to
fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the device is
used exceeds the applicable RF compliance level above, the device should be observed to verify normal operation. If abnormal performance is
observed, additional measures may be necessary, such as re-orienting or relocating the device.
b
Over the frequency range 150 kHz to 80 MHz, the field strengths should be less than 3 V/m.
Recommended Separation Distances between Portable and Mobile RF Communications Equipment and This Device: The device is
intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user
of this device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF
communications equipment (transmitters) and this device as recommended below, according to the maximum output power of the
communications equipment.
r
M
ated
axiMUM
P
o
ower
UtPUt of
t
ransMitter
w
0.01
0.1
1
10
100
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in meters (m) can be estimated using the
equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to
the transmitter manufacturer.
Note 1: At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
Note 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects,
and people.
20
iec 60601 t
c
est
oMPliance
l
evel
3 Vrms
3 V/m
s
eParation
150
H
80 MH
k
z to
d = 1.2
0.12
0.38
1.2
3.8
12
e
lectroMagnetic
l
evel
Portable and mobile RF communications equipment should be used
no closer to any part of the device, including cables, than the
recommended separation distance calculated from the equation
applicable to the frequency of the transmitter.
Recommended separation distance
d = 1.2
d = 1.2
d = 2.3
where P is the maximum output power rating of the transmitter in
watts (W) according to the transmitter manufacturer and d is the
recommended separation distance in meters (m).
Field strengths from fixed RF transmitters, as determined by an
electromagnetic site survey
level in each frequency range.
Interference may occur in the vicinity of equipment marked with the
following symbol:
d
a
istance
ccording to
M
80 MH
800 MH
z
z to
d = 1.2
0.12
0.38
1.2
3.8
12
e
-g
nvironMent
80 MHz to 800 MHz
800 MHz to 2.5 GHz
, should be less than the compliance
a
b
f
t
reqUency of
ransMitter
800 MH
2.5 gH
z
z to
d = 2.3
0.23
0.73
2.3
7.3
23
Uidance
z
U
M
ser