Barco BarcoGraphics Maxwell/ 6300 User Manual page 275

Serial communications lcd-dlp projectors
Hide thumbs Also See for BarcoGraphics Maxwell/ 6300:
Table of Contents

Advertisement

n
Description :
Read the run time when the warning menu, indicating the
end of life of the lamp, first occurs. This warning menu is
displayed on the screen and is repeated every 30 minutes
n
Command :
Command[0]
Command[1]
n
Data :
No data bytes.
n
Return data :
The return data-transfer being the lamp warning run time
in seconds consists of four data bytes. The first byte is the
most significant byte !
Formula :
Lamp warning run time (seconds)
= Data[0]*256 3 + Data[1]*256 2 + Data[2]*256 + Data[3]
n
Projector type :
Not all projectors support this command.
n
Example :
Read the lamp warning run time of a projector with
address \x01. Suppose the message appears at 1000 hours.
\x76
\x8c