n
Description :
Read the run time when the warning menu, indicating the
end of life of the lamp, first occurs. This warning menu is
displayed on the screen and is repeated every 30 minutes
n
Command :
Command[0]
Command[1]
n
Data :
No data bytes.
n
Return data :
The return data-transfer being the lamp warning run time
in seconds consists of four data bytes. The first byte is the
most significant byte !
Formula :
Lamp warning run time (seconds)
= Data[0]*256 3 + Data[1]*256 2 + Data[2]*256 + Data[3]
n
Projector type :
Not all projectors support this command.
n
Example :
Read the lamp warning run time of a projector with
address \x01. Suppose the message appears at 1000 hours.
\x76
\x8c
275