n
Description :
Read the actual value of the clamp delay.
n
Command :
Command[0]
Command[1]
n
Data :
No data bytes.
n
Return data :
Data[0] = value of the clamp delay.
n
Example :
Read the actual value of the clamp delay of a projector
with address \x01. Suppose the clamp delay equals \x00.
Transmit
Start
Projector address
Command[0]
Command[1]
Checksum
Stop
\x21
\x67
\xfe
\x01
\x21
\x67
\x89
\xff
131