Parameter Function
1
Ignition power as %
2
Maximum heating power (%)
3
Anti-cycle timer (minutes)
4
Minimum heating outlet temperature
5
Maximum heating outlet temperature
6
Not used
tS
E@sy remote surveillance
F
Type of boiler
E
External actuator (depending on system)
P
Post-circulation with pump in heating mode
Activation/deactivation of Domestic hot
C
water function
PU
Pump speed control
r
Heating setpoint range
P
Temperature control by external sensor
P6
Gradient shift
P5
Gradient adjustment
T
Test function
A
Not used
b0
Second zone set-point
b1
Not used
b2
Post Domestic hot water timer in minutes
b3
Not used
b4
Programmer action
b5
Not used
b7
Not used
b8
Not used
Important!! The parameters P5 , P6 and P9 are only activated if the external sensor is connected.
To return to the standard displays, press the Menu button.
MENU TABLE
Adjustment range
00 to 99 %
(step: 1%)
00 to 99 %
(step: 1%)
00 to 07 minutes
(step: 1 minute)
25° to 42 °C if parameter r = 00
42° to 81 °C if parameter r = 01
26° to 75 °C if parameter r = 00
43° to 82 °C if parameter r = 01
00 to 99
0 or 1
00 to 03
00 to 03
from 01 to 15 minutes or C0
00 or 01
U0 or U1
00 or 01
90 or 91
- 20 to + 20 °C
0_1 to 5_0
25 to 82
00 to 30
0 to 2
0 on heating and tank reheating
1 on tank reheating
2 on heating
Factory settings
55
Consult the manufacturer
before changing this
parameter
66
02
42
82
45
0
Do not alter if the E@sy
system is not connected
03 do not alter (boiler
with tank)
00 do not alter
02
00
U1
01
90
0
0_9
Not used
75
00
0
39