Ignition power output setting 1
This parameter limits the power of the boiler in the ignition phase.
Possibility of adjusting ignition between maximum power (display of
"99", i.e. 100%) and minimum power (display of "00", i.e. 0%).
The percentage expresses the usable power value between the
minimum and maximum power value.
Use the
and
buttons in menu 1 to select the required value.
The factory-set value is given in the menu table.
Maximum heating power regulation 2
This parameter limits the power of the boiler in the heating phase.
The percentage expresses the power value between the minimum and
maximum power value.
Use the
and
buttons in menu 2 to select the required value.
The factory-set value is given in the menu table.
Anti-cycle timer 3
This parameter sets the delay between 2 successive burner ignitions in
heating mode.
It is possible to select an ignition delay of between 1 and 7 minutes.
Use the
and
buttons in menu 3 to select the required value.
The factory-set value is given in the menu table.
Minimum heating outlet temperature 4
This parameter sets the minimum heating outlet temperature in relation
to r.
Use the
and
buttons in menu 4 to select the required value.
The factory-set value is given in the menu table.
Maximum heating outlet temperature 5
This parameter sets the maximum heating outlet temperature in
relation to r.
Use the
and
buttons in menu 5 to select the required value.
The factory-set value is given in the menu table.
Selection of boiler type F
Pre-set in factory:
This parameter must not be altered.