Ariston GENUS HE 35 Plus Installation And Servicing Instrucnion page 24

Type c boilers
Table of Contents

Advertisement

11.1 Fitting the coaxial flue (Ø 60/100 Horizontal)
C
:
ONTENTS
1
S
O-R
(60mm)
X
ILICONE
ING
1
E
(90
)
O
X
LBOW
2
W
S
(I
X
ALL
EALS
NTERNAL
1
F
P
X
LUE
IPE INCLUDING
1
F
C
X
LUE
LAMP
1
S
X
CREWS
1x Seal
Once the boiler has been positioned on the wall, insert the elbow into the socket and rotate to the required position.
possible to rotate the elbow 360
Using the flue clamp, seals and screws supplied (Fig 11.5) secure the elbow to the boiler.
The 1 metre horizontal flue kit (3318073) supplied is suitable for an exact X dimension of 815mm.
Measure the distance from the face of the external wall to the face of the flue elbow (X - Fig 11.4), this figure must now be
subtracted from 815mm, you now have the total amount to be cut from the plain end of the flue.
Draw a circle around the outer flue and cut the flue to the required length taking care not to cut the inner flue, next cut the inner
flue ensuring that the length between the inner and outer flue is maintained. (Fig 11.5).
e.g.
X = 555mm
815-555 = 260mm (Length to be cut from the plain end of the flue).
Once cut to the required length, ensure that the flue is free from burrs and reassemble the flue. If fitting the flue from inside of
the building attach the grey outer wall seal to the flue terminal and push the flue through the hole, once the wall seal has
passed through the hole, pull the flue back until the seal is flush with the wall. Alternatively, the flue can be installed from
outside of the building, the grey outer seal being fitted last.
Seal
24