Ariston GENUS HE 35 Plus Installation And Servicing Instrucnion page 63

Type c boilers
Table of Contents

Advertisement

B
IS
THERE STILL
YES
YES
A PROBLEM?
NO
NO
NORMAL
OPERATION
FAULTS
1 1
Drawing D.H.W:
When you turn on a tap
burner switches off
2 2
Drawing D.H.W:
radiators heat up in summer mode
3 3
Drawing D.H.W:
insufficient hot water
temperature
4 4
Drawing D.H.W:
noisy operation
5 5
Decrease/increase
heating circuit pressure
6 6
Repeated shutdowns
7 7
Repeated intervention of safety thermostat
8 8
When cold water tap turned off, the boiler
ignites
9 9
Insufficient radiator temperature
POSSIBILE CAUSES
- check temperature probes
- faulty D.H.W. flow switch
- faulty 3-way valve
- check temperature probes
- check gas pressures
- check water flow rate
- primary heat exchanger faulty or
lime-scale deposits
- low heating system water pressure
- check gas pressures
- check temperature probes
- check for leaks on the heating circuit
- faulty filling-loop
- expansion vessel faulty
- faulty detection electrodes
- check gas settings
- check flame detection electric circuit
- check temperature probes
- overheat thermostat not calibrated correctly
- air in primary water circuit
- drop in pressure in the water mains, with
consequent water hammer
- check C.H. temperature probe
- check by-pass and pump speed
- check gas pressures
FC P014