Ariston GENUS HE 35 Plus Installation And Servicing Instrucnion page 41

Type c boilers
Table of Contents

Advertisement

F
F
Selection of Secondary Output operation E
Only activated if peripheral interface card connected (option)
For connection of peripherals to the motherboard, refer to the user
instructions for the Clima Manager or the external sensor. Parameter E
is altered by the
and
00 Zone valve - factory setting
01 NOT USED
02 NOT USED
03 NOT USED
Circulation pump post-circulation P
The appliance allows variation of the post-circulation period of the
circulation pump after extinction of the burner. Adjustable from 1 to 15
minutes or continuous ( CO ).
Use the
and
buttons in menu P to select the required value.
The factory-set value is given in the menu table.
Comfort Function : activation/deactivation of the Domestic hot
water and tank reheating functions C
00 Domestic hot water and tank reheating functions deactivated
01 Domestic hot water and tank reheating functions activated
When the function is activated, the yellow indicator light 31 comes on.
To deactivate the Comfort function, press the
The yellow indicator light 31 goes out.
Use the
and
buttons in menu C to select the required value.
The factory-set value is given in the menu table.
Circulation pump speed P
U0 - Fixed speed operation
U1 - Variable speed operation
Use the
and
buttons in menu P to select the required value.
The factory-set value is given in the menu table.
Heating temperature range setting r
00 - possibility of adjusting the temperature from 25°C to x in menu 4
possibility of adjusting the temperature from x+1 to 75°C in menu 5
where x ≤ 44 °C
01 - possibility of adjusting the temperature from 42°C to y in menu 4
- possibility of adjusting the temperature from y+1 to 82°C in menu 5
where y ≤ 81 °C
Use the
and
buttons in menu r to select the required value.
The factory-set value is given in the menu table.
Temperature control by external sensor P
(Only activated if the external sensor is installed)
" 90 " Temperature adjustment by external sensor deactivated (external
sensor not installed).
" 91 " Temperature adjustment by external sensor activated (external
sensor installed).
Use the
and
buttons in menu P to select the required value.
The factory-set value is given in the menu table.
programming buttons.
button.
COMFORT
41

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents