Section 5 Operations

The operator control panel for the Falcon 160
CE Laminator is located on the front of the machine, to
the right of the front operating position.
For an illustration of the complete front control
panel, please refer to Figure 5.1.1. The names and
functions of these controls are as follows:
INFORMATION
When any command is pressed on the
control panel, a "beep" will sound. If the
command is held down, the panel will
"beep" only once.

5.1 Control Panel

( 1 ) STANDBY: If flashing, the machine is in standby
mode. This will occur after 3 hours of no activity. To wake
the laminator from standby mode or manual engage standby
mode, press STANDBY.
0
JOB
© GBC Films Group April 2000
SEL
SAV
STANDBY
1
( 2 ) TOP TEMP DISPLAY : The display will show the
set point temperature of the top main roller as the default
display. When the top roller temperature has reached in
o
the +/- 6
F range of the set point, the display will be
solid. When outside of this range, the display will flash.
TOP TEMP
68
( 3 ) TOP TEMP
: When pressed, will increase the
set point value of the top main roller in increments of 2
degrees. If held down, it will only increase to the maximum
temperature setting of 290
TOP TEMP
68
( 4 ) TOP TEMP
: When pressed, will decrease the
set point value of the top main roller in increments of 2
degrees. If held down, it will only decrease to the minimum
temperature setting of 68
TOP TEMP
68
Operations
BOT TEMP
68
2
o
o
F ( 143
C ).
3
BOT TEMP
68
o
F ( 20
o
C ).
BOT TEMP
68
4
Page 5 - 1