Connecting Twisted Pair (Rj-45,Cat3, Cat5,); Connecting Twisted Pair (Cat5E Or Better,) - GarrettCom Magnum 6K16V Installation And User Manual

Managed fiber switch
Hide thumbs Also See for Magnum 6K16V:
Table of Contents

Advertisement

Magnum 6K16V Managed Fiber Switch
(9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx
are the diameters of the core and the core plus the cladding respectively). Single-mode
fiber allows full bandwidth at longer distances, and may be used to connect 10 Mb nodes
up to 10 Km apart, or 18Km with the 6K-SSC.
The same procedures as for multi-mode fiber applies to single-mode fiber
connectors. Follow the steps listed in Section 3.2.2 above.
3.2.4
Connecting Twisted Pair (RJ-45,CAT3, CAT5, Unshielded or Shielded)
The RJ-45 ports of the Magnum 6K16V can be connected to the following two
media types: 100BASE-TX and 10BASE-T. CAT 5 cables should be used when making
100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be
used. In either case, the maximum distance for unshielded twisted pair cabling is 100
meters (328 ft).
Media
Twisted Pair (CAT 3, 4, 5)
Twisted Pair (CAT 5)
NOTE : It is recommended that high quality CAT. 5 cables (which work for both 10 Mb
and 100Mb) be used whenever possible in order to provide flexibility in a
mixed-speed network, since dual-speed ports are auto-sensing for either 10 and
100Mb/s.
The following procedure describes how to connect a 10BASE-T or 100BASE-
TX twisted pair segment to the RJ-45 port. The procedure is the same for both
unshielded and shielded twisted pair cables.
1.
Using standard twisted pair media, insert either end of the cable with an RJ-45
plug into the RJ-45 connector of the port. Note that, even though the connector is
shielded, either unshielded or shielded cables and wiring may be used.
2.
Connect the other end of the cable to the corresponding device
3.
Use the LINK LED to ensure proper connectivity by noting that the LED will be
illuminated when the unit is powered and proper connection is established
3.2.5
Connecting Twisted Pair (CAT5E or better, Unshielded or Shielded)
The RJ-45 Gigabit ports of the Magnum 6K16V can be connected to the media
types, 1000BASE-T or CAT 5E or better 100-ohm UTP or shielded twisted pair (STP)
balanced cable. The CAT 5E or better 100-ohm UTP or shielded twisted pair (STP)
balanced cable is recommended to use when making 1000BASE-TX connections. In
either case, the max distance for unshielded twisted pair cabling is 100 meters (328 ft).
Media
Twisted Pair (CAT 5E)
NOTE : It is recommended that high quality CAT. 5E cables (which work for both 100
Mb and 1000Mb) be used whenever possible in order to provide flexibility in a
mixed-speed network.
www GarrettCom com
.
.
Installation and User Guide (06/04)
IEEE Standard
10BASE-T
100BASE-TX
IEEE Standard
1000BASE-T
20
Connector
RJ-45
RJ-45
Connector
RJ-45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents