Connecting Single-Mode Fiber Optic; Connecting Twisted Pair (Rj-45,Cat3, Cat5) - GarrettCom Magnum 4K24F Installation And User Manual

Magnum 4k24-series
Table of Contents

Advertisement

Magnum 4K24 Switches Installation and User Guide
female jacks of the FPM until it clicks and secures.
3.2.3

Connecting Single-Mode Fiber Optic

When using single-mode fiber cable, be sure to use single-mode fiber port
connectors. Single-mode fiber cable has a smaller diameter than multi-mode fiber cable
(9/125 microns for single-mode, 50/125 or 62.5/125 microns for multi-mode where xx/xx
are the diameters of the core and the core plus the cladding respectively). Single-mode
fiber allows full bandwidth at longer distances than multi-mode, and may be used to
connect nodes or switched ports, to 20+Km distance with the FKM-SSC and 40+Km
with the "long reach" FKM-SSCL.
The same procedures as for multi-mode fiber applies to single-mode fiber
connectors. Follow the steps listed in Section 3.2.2 above.
3.2.4
Connecting Twisted Pair (RJ-45,CAT3, CAT5, Unshielded or
Shielded)
The RJ-45 ports of the Magnum 4K-Series can be connected to the following
two media types: 100BASE-TX and 10BASE-T. CAT 5 cables should be used when
making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3
may be used. In either case, the maximum distance for unshielded twisted pair cabling is
100 meters (328 ft).
Media
Twisted Pair (CAT 3, 4, 5)
Twisted Pair (CAT 5)
NOTE : It is recommended that high quality CAT. 5 cables (which work for both 10 Mb
and 100Mb) be used whenever possible in order to provide flexibility in a
mixed-speed network, since dual-speed ports are auto-sensing for either 10 and
100Mb/s.
The following procedure describes how to connect a 10BASE-T or 100BASE-TX
twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded
and shielded twisted pair cables.
1.
Using standard twisted pair media, insert either end of the cable with an RJ-45
plug into the RJ-45 connector of the port. Note that, even though the connector is
shielded, either unshielded or shielded cables and wiring may be used.
2.
Connect the other end of the cable to the corresponding device
3.
Use the LINK LED to ensure proper connectivity by noting that the LED will be
illuminated when the unit is powered and proper connection is established.