Magnum 4K16 Switches Installation and User Guide
3.2

Connecting Ethernet Media

The Magnum 4K16 Switches are specifically designed to support all
standard Ethernet media types within a single Switch unit. This is
accomplished by complementing standard RJ-45 copper parts with a family of
Fiber-port Modules (FKMs) which can be individually selected and configured
per-port. See Section 2.4 for a description of the FKMs.
The various media types supported along with the corresponding IEEE
802.3 and 802.3u standards and connector types are as follows:
IEEE Standard
Fiber:
100BASE-FX
small form factor
Copper:
10BASE-T & 100BASE-TX twisted pair 100m (328 ft)
1
3.2.1

Connecting Fiber Optic ST-type, "twist-lock"

The following procedure applies to installations using a FKM with ST-type fiber
connectors. This procedure applies to ports using a FKM-MST.
1.
Before connecting the fiber optic cable, remove the protective dust caps from the
tips of the connectors on the FKM. Save these dust caps for future use.
2.
Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue
dampened in alcohol. Make certain the connectors are clean before connecting.
Note:
One strand of the duplex fiber optic cable is coded using color
bands at regular intervals; you must use the color-coded strand on the
associated ports at each end of the fiber optic segment.
3.
Connect the Transmit (TX) port (light colored post) on the Magnum FKM to the
Receive (RX) port of the remote device. Begin with the color-coded strand of
the cable for this first TX-to-RX connection.
4.
Connect the Receive (RX) port (dark colored post on the PM) to the Transmit
(TX) port
of the remote device. Use the non-color coded fiber strand for this.
5.
The LINK LED on the front of the FKM will illuminate when a proper
connection has been established at both ends (and when power is ON in the unit).
If LINK is not lit after cable connection, the normal cause is improper cable
polarity. Swap the fiber cables at the FKM connector to remedy this situation.
www GarrettCom com
.
.
Media Type
1
m
m
Fiber
2
sgl.m
Fiber
2
sgl.m
Fiber
1
m
m
Fiber
mm = multi-mode
Max. Distance
2.0km (6,562 ft)
20.0km (95K ft) FKM-SSC
40.0km (12K ft) FKM-SSCL
2.0km (6,562 ft)
2
sgl.m = single-mode
15
(12/05)
Port Module
FKM-MSC, -MST
FKM-MTRJ,
RJ45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Magnum 4k-seriesMagnum 4k16r

Table of Contents

Save PDF