The Installation Space; Dimensions And Clearances - GE Monogram ZICP720 Installation Instructions Manual

Professional style bottom-freezer refrigerators
Table of Contents

Advertisement

Design Guide
THE INSTALLATION
SPACE
The installation
space must be 71-1/2",
f
71-1/2" F inished Width
........................................
f
ll
2-5'16"
',
"1 Wall
/k
5/'j
E!ectrical
f
24-3/ 6" -I View
--/
_
6
, mm_
6"
|
!,
1
t
max I
10
i
]u
.
83-I/2"tl
'
75 From
rain J_ 24"Cutout
i
Finished
Finished I
Depth
,
Floorto
• I
,,
Bottomof
upenmg | _"
W
"
5"
Electrical
I
/
"
t
aterSupply ,, WaterSupply T
Area
"
i
I
_
j
/ I,
i
Z ............
26 ...................
\
/:
............
26" .................
\
3-1/2"
3-1/2"
Water And Electrical
Locations
Electrical and water supply must be located
as shown.
The cutout
depth must be 24"
The refrigerator
will project forward,
slightly
beyond adjacent
cabinetry,
depending
on your
installation.
Cutout
depth beneath
a soffit:
When installed beneath a soffit, the soffit cannot
exceed the 24" installation
depth shown. The top
case trim overlaps the bottom of the soffit.
Additional
Specifications
cA separate
115 volt 60Hz., 15 or 20 amp power
supply is recommended
for each product,
An
individual
properly
grounded
branch circuit or
circuit breaker is recommended.
Install properly
grounded
3-prong electrical
receptacles
recessed
into the back wall, Electrical must be located on
rear wall as shown,
NOTE: GFI (ground fault interrupter)is
not
recommended.
Both water lines can enter the opening through
the floor or back wall. Route GE SmartConnect"
kit or 1/4" O.D. copper tubing between the cold
water line and the water connection
location.
The tubing should be long enough to extend to
the front of the refrigerator.
Installation
of an
easily accessible shut-off valve in the water
line is required.
DIMENSIONS AND CLEARANCES
71-1/2"
25-3/4"
Case Width
Case Depth
83-1/2"
at Rear
28-11/16"
Depth Including
Handles
72"Frame
to Frame '
Width
Shipping height. T he
refrigerators c anbe
adjusted to fit intoa
cutoutthatis 83-1/2"
min. t o 84-1/2" m ax.
Notethatthetopcase
trim atthefrontis 1/2"
higher andwill overlap
uppercabinetry or
soffit.Useleveling legs
andwheelsfor a
maximum 1"height
adjustment.
Product
Clearances
These refrigerators
are equipped with a 2-position
door stop. The factory
set 130 ° door swing can be
adjusted to 90 ° if clearance to adjacent cabinets
or walls is restricted.
25"_
Min.toi
130 ° Door
Wall
I
/L
0 ,!
H
130 ° Door
Swing
Swing
11
q-'
'-F
i
L
__25"__I
Min.to
Wall
/,,
,,
"":::",,:::,,::::!
Allow 25" minimum clearance for a full 130° door
swing. Allow 15" for pan removal.
5" minimum clearance is required when door swing
is adjusted to 90°, If the 90° door stop position is
used, pan access is maintained, but pan removal
is restricted.
See illustrations
on pages
4 and 5 to determine
door
swing interaction
with
adjacent cabinets
or
countertops,
T
90 ° Door
1 23-7/8"
Swing
/ Behind
,
!, _Frame
L!
i
!i 36-3/4-
90o
.........
5" Minimum to
Wall

Advertisement

Table of Contents
loading

Table of Contents