Download Print this page

GE Monogram ZIC360NX Specification

36" built-in side-by-side refrigerator
Hide thumbs Also See for Monogram ZIC360NX:

Advertisement

Quick Links

ZIC360NX
GE Monogram
Dimensions and Installation Information (in inches)
The Installation Space
The finished cutout width
must be 35-1/2" .
84-1/2" max
83-1/2" min
The cutout depth must be 24"
The refrigerator will project forward, slightly beyond adjacent
cabinetry, depending on your installation.
The cutout depth beneath a soffit
When installed beneath a soffit, the soffit cannot exceed the
24" installation depth shown. The top case trim overlaps the
bottom of the soffit.
Electrical
A 115V, 60Hz., 15 or 20 amp power supply is required. An
individual properly grounded branch circuit or circuit breaker
is recommended. Install a properly grounded 3-prong
electrical receptacle recessed into the back wall. Electrical
must be located on rear wall as shown.
Note: GFI (ground fault interrupter) is not recommended.
Water Line
All models are equipped with an automatic icemaker. The
water line can enter the opening through the floor or back
wall. Route GE SmartConnect
between the cold water line and the water connection
location at the front of the refrigerator. The installation of an
easily accessible shut-off valve in the water line is required.

Product Dimensions

35"
Case Depth:
Case Width
25-3/8" Framed Models
25-3/4" Stainless Steel Models
*84" From
*83-1/2"
Floor to
at
Top Frame
Rear
36"
Frame to Frame Width
Depth Including Handles:
26-7/8" Framed Models
27-3/4" Stainless Steel Models
28-11/16" Professional Models
For answers to your Monogram,
GE
appliance questions, visit our website at
®
429Dia9
ge.com or call GE Answer Center
800.626.2000.
36" Built-In Side-by-Side Refrigerator
®
35-1/2"
Finished Width
2-5/16"
6"
10"
Electrical
Area
Floor to Bottom
24" Cutout Depth
Finished
Opening
Cold Water
5"
5"
Supply
3 1/2"
3 1/2"
696Dia7
Kit or 1/4" O.D. copper tubing
* Shipping Height. The
refrigerator can be adjusted to
fit into a cutout that is 83-1/2"
min. to 84-1/2" max. height. The
top case trim at the front is 1/2"
higher and will overlap upper
cabinetry or soffit. Use leveling
legs and wheels for a maximum
1" height adjustment.
GE Profile
or
®
service,
®
Door Swing Clearances
The installation must allow for clearances to adjacent walls or
cabinets. These refrigerators are equipped with a 2-position
Wall View
door stop. The factory-set 130° door swing can be adjusted to
90° if clearance to adjacent cabinets or walls is restricted.
75" From
130° Door Swing
of Electrical
Area
Note: Icemaker
water connection
is at the front.
130°
Allow 25" minimum clearances for a full 130° door swing.
605Dia20
Allow 15" for pan removal.
• 4" minimum clearance is required when the door swing is
adjusted to 90°. If the 90° door stop position is used, pan
access is maintained, but pan removal is restricted.
• See door swing illustrations to determine interaction with
adjacent cabinets or countertops.
ZUG2, ZUGSS2 Unified Grille Panel Kit
• If you are installing two refrigerators side by side, the
installation space must be 71-1/2" wide.
Note: Additional cutout width may be required when side
panels are used. Add side panel thickness to the finished
cutout to calculate rough-in width.
• The water and electrical locations for each product must
be located as shown.
• A separate 115V, 60Hz., 15 or 20 amp power supply is
recommended for each product.
84-1/2" max
83-1/2" min
Finished
Opening
3-1/2"
25"
Min. to
Wall
90° Door Swing
90°
5" Min. for Professional Models
605Dia21
71-1/2" Finished Width
2-5/16"
24-3/16"
Electrical
6"
10"
10"
24" Cutout
Depth
5"
Water Supply
Water Supply
26"
26"
696Dia8
Specification Created 6/08
23-7/8"
Behind
Frame
36-3/4"
4" Min. to Wall
Wall View
75" From
Floor to Bottom
of Electrical
Area
5"
3-1/2"
Listed by
Underwriters
Laboratories
110112

Advertisement

loading

Summary of Contents for GE Monogram ZIC360NX

  • Page 1: Product Dimensions

    Kit or 1/4" O.D. copper tubing ™ between the cold water line and the water connection location at the front of the refrigerator. The installation of an easily accessible shut-off valve in the water line is required. Product Dimensions 35"...
  • Page 2 For answers to your Monogram, GE Profile ® 696Dia9 appliance questions, visit our website at ® ge.com or call GE Answer Center service, ® 800.626.2000. Door Handles The supplied handles can be adjusted to accommodate both framed or overlay panels. Custom handles of your choice, supplied by your cabinetmaker, can also be installed.
  • Page 3 3/4" Overlay Panel 34-1/8 For answers to your Monogram, GE Profile ® appliance questions, visit our website at ® ge.com or call GE Answer Center service, ® 800.626.2000. 3/4" Overlay Panel Dimensions For a more custom appearance, overlay panels may be installed 5/16"...
  • Page 4 For answers to your Monogram, GE Profile ® appliance questions, visit our website at ® ge.com or call GE Answer Center service, ® 800.626.2000. Frameless Cabinets: The case trim overlaps cabinets at the top and sides. Therefore, frameless cabinets may require filler strips to prevent interference with cabinet door swing.
  • Page 5 Top View 90° Door Swing (Optional setting) Scale 1:1 For answers to your Monogram, GE Profile ® appliance questions, visit our website at ® ge.com or call GE Answer Center service, ® 800.626.2000. Refrigerator Door ™ Case Trim 23-7/8" From Rear of Refrigerator 1/4"...
  • Page 6 • Model ZIC360NXLH – Left-handed door swing (Door panels required) For answers to your Monogram, GE Profile ® appliance questions, visit our website at ® ge.com or call GE Answer Center service, ® 800.626.2000. ™ ZIC360NRLH.EPS Specification Created 6/08 110112...

This manual is also suitable for:

Monogram zic360nxlhMonogram zic360nxrh