Design Guide; The Installation Space - GE Monogram ZDOD240HSS Design Manual With Installation Instructions

Outdoor/indoor
Table of Contents

Advertisement

THE INSTALLATION SPACE

NOTE:
Handle and
handle standoff
depth is 2-7/8"
Free-Standing – Use canopy top Built-In – Remove canopy top
Choose the location:
• This product has been designed as a free-standing unit;
however, if desired, it may also be built-in.
• These products may be closed in on the top and
three sides as long as the front is unobstructed for
air circulation and proper access to the door.
• Do not operate these products where the temperature
will go below 45°F (7°C) or above 120°F (49°C).
• Unit must be installed on a structurally sound and
level surface strong enough to support a fully loaded
refrigerator, or approx. 250 lbs.
• The Outdoor/Indoor Refrigerator can be used
free-standing.
*For a standard installation: The product must be installed
so that the stainless steel front will project 1-7/8" forward
of adjacent cabinets. This position will allow a full door swing
and prevent interference with adjacent cabinetry.
The opening between cabinets must be 23-3/4" minimum.
**For a flush installation: Install a 1/2"-wide filler strip on
the hinge side. The filler strip will act as a spacer between
the door case and adjacent cabinets and will prevent
interference with the cabinet door swing. Recess the filler
strip 1-7/8" back from the front face of the refrigerator, or
even with the front edge of the product case (behind the
gasket). The width of the opening must be 24-1/2" (including
the 1/2" filler strip).
Additional Specifications
• A 120 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch circuit
or circuit breaker is recommended. Install a properly
grounded 3-prong electrical receptacle recessed into
the back wall as shown. Electrical must be located
on rear wall as shown. THIS PRODUCT MUST BE
CONNECTED TO A POWER SOURCE WITH GROUND
FAULT CIRCUIT INTERRUPTER (GFCI) PROTECTION
WHEN INSTALLED IN AN OUTDOOR LOCATION. LOCAL
CODES MAY REQUIRE A SEPARATE CIRCUIT.

Design Guide

(if needed)
4
THE INSTALLATION SPACE (cont.)
Installation
Filler panel or cleat
to be set back even
with front of case.
CABINET
Front edge of product case
Front face
These products will fit flush
to adjacent cabinets when
installed with a 1/2" filler panel
or cleat. The filler panel should
be recessed or set back behind
the door and even with the front
edge of the product case.
Standard
Installation
CABINET
Front edge of product case
1-7/8"
Front face
In a standard installation,
the product will project 1-7/8"
forward of adjacent cabinets.
Flush
1/2"
CABINET
110°
120°
CABINET
110°
120°

Advertisement

Table of Contents
loading

This manual is also suitable for:

Monogram zdod240