Basic Setting With The Control Panel V810 Or V820 - Duerkopp Adler 550-867 Service Instructions Manual

Hide thumbs Also See for 550-867:
Table of Contents

Advertisement

2.13.2

Basic setting with the control panel V810 or V820

44
1
Caution: Risk of injury!
The adjustment of the potentiometer is done with the main switch
switched on.
Work with utmost caution.
Loosen the stop screw 1 for the potentiometer 2.
Keep the key "P" pressed and turn on the main switch.
Enter the technician level.
Select the parameter "F-188".
Actuate the key "E".
The current Speedomat grade (for example 11) and the
corresponding sewing speed limitation (for example 2860) are
displayed.
Turn the potentiometer shaft until the Speedomat grade "07" and
the corresponding maximum sewing speed of 3800 rpm resp. 3400
rpm (depending on the subclass) are indicated on the display.
Tighten the stop screw 1.
Check the setting.
2