seam section
60
Select the individual seam sections by clicking on them and enter
the corresponding seam parameters.
The selected seam segment is displayed with a raised bar.
monitored (red)
Parameter
Free/SAB
Max. speed
Stitch length
St l corr.fac.
Dist. Length
Thread tension
Thread tens.
Stop at
GB thread ten.
Komp file
Lift Stroke
Lift stroke knee
Bartack stitches
(forwards/backwards)
Sewing in the label
TT ON/OFF
section
After setting the seam parameters for all of the seam sections,
press the button "Save".
not monitored
(green)
Description
Indicates whether a free seam segment
or a tearing seam is activated
maximum speed for the current seam segment
stitch length for the current seam segment
Correction of the stitch length depending
on the material
Distance between the two strips on the
sewing material
Tolerance range (lower value, top value)
and number of tolerance stitches
Value of power supply in % (only with ETT)
strip, stitch counting or manually (Pedal – 2)
Selection of a Teach-in file (only with ETT)
Lift stroke of the alternating sewing feet
Lift stroke upon activating the knee lever
(Rapid stroke adjustment)
Number of bartack stitches
Activates the seam scanner
Trims the thread at the end of the seam