Electrical Connection – US & Canada
1. Verify that the actual voltage at the electrical service connection is compatible with the specifications on the
brewer's serial number label. Make sure the electrical service includes neutral.
2. The temperature and water tank fill level are pre-set at the factory. There is no need to turn off the heaters
during the installation process. The heaters are disabled by the control board until the tank is full of water. The
heating process will start automatically when the tank has filled.
3. The CBS-2041e is factory equipped with a 120 V cord and plug. The CBS-2042e has only a terminal block for
connecting the incoming power wires. Consult local codes to determine if a cord and plug can be installed, or if
the unit must be hard wired.
4. A fused disconnect switch or circuit breaker on the incoming power line must be conveniently located near the
brewer, and its location and markings known to the operators.
5. The body of the brewer must be grounded to a suitable building ground.
A ground lug is provided in the brewer next to the power terminal block.
Use only 10 gauge copper wire for grounding.
6. Electrical connections must be secured in-place within the unit to meet
national and local standards.
7. Finally, connect the incoming power wires to the terminal block as shown in accordance with applicable codes.
CBS-2041e
This model can be connected to 120 VAC or 120/208-240 VAC
Factory Configuration
120 VAC, 3 wires
GROUND
L1
CBS-2042e
This model can be connected only to 120/208-240 VAC
N
L2
L2 - NOT USED
CORD WITH
NEMA 5-20P PLUG
GROUND LUG
GROUND
WIRE
Optional Field Conversion*
120/208-240 VAC, 4 wires
Step 1: Remove the factory provided 120 V cord &
plug from the terminal block.
Step 2: Connect the incoming wires to the terminal
block in accordance with applicable codes.
GROUND LUG
GROUND
WIRE
*This procedure must be performed only by a qualified
service technician or electrician.
Notice: In order for this product to comply with the
requirements of the Underwriters Laboratories listing,
the following conditions apply:
1.) This unit must be hard wired for 120/208-240 VAC.
2.) Once the unit is converted to 120/208-240 VAC
operation, it cannot be converted back to 120
VAC operation.
L1
N
L2
120V
120V
N
208-240V
6
Warning: To prevent
electrical shock, this
unit must be properly
grounded.
L1
N
L2
120V
120V
N
208-240V