iNSTALLATiON
iNSTRUCTiONS
J
Remove
the
drain plug
Fig.23
j
Continuous
drain hose
Fig.24
Water
drainage:
During dehumidifying
modes,
remove the drain
plug from the back of the unit; install the drain
connector
(5/8" universal
female mender)
with
3/4"" hose (not included).
For the models
without drain connector,
just attach the drain
hose to the hole. Place the open end of the
hose directly over the drain area in your
basement
floor. Please refer to Fig. 23 & 24.
When the water level of the bottom tray reaches
a predetermined
level, the unit beeps 8 times,
the digital display area shows "P1 ." At this time
the air conditioning/dehumidification
process will
immediately
stop. However, the fan motor will
continue to operate
(this is normal).
Carefully
move the unit to a drain location,
remove the bottom drain plug and let the
water drain away (Fig. 25).
Restart the machine
until the "P1" symbol disappears.
If the error
repeats,
call for service.