CONTINUOUS DRAINAGE
To operate the unit continuously without manually emptying the tank, follow these steps:
1. Remove the drain plug from the back of the unit and retain it for future
use.
2. Connect the drainage hose included with the unit to the drainage port as
shown.
3. Connect the other end of the hose into a drain.
Please note:
The drain must be at or below the level of the drainage port.
The full water tank indicator will not work when the unit is being continuously drained.
To extend the drainage hose, you can add an extension hose with an overall diameter of approximately 0.7"
(18 mm).
HEATING MODE
MODEL AC-14000H ONLY.
In order to properly exhaust cool air, make sure the exhaust hose and window kit are installed correctly.
Set up the air conditioner for continuous drainage using the included drain tube.
The working range for the heating function is 45°F to 77°F. The unit may not provide optimal heating if used
in temperatures outside this range.
CLEANING & MAINTENANCE
CLEANING YOUR PORTABLE AIR CONDITIONER
Always unplug the air conditioner from the power supply before cleaning. To maximize the efficiency of the air
conditioner, regularly clean the unit.
CLEANING THE HOUSING
Use a soft, damp cloth to wipe the body clean.
Never use strong chemicals, gasoline, detergents, chemically-treated cloths, or any other cleaning solutions
to clean the air conditioner, as these can all potentially damage the unit's housing.
13