Download Print this page
NewAir AC-10100E Owner's Manual

NewAir AC-10100E Owner's Manual

Portable air conditioner
Hide thumbs Also See for AC-10100E:

Advertisement

Quick Links

PLEASE READ AND SAVE THESE INSTRUCTIONS
NewAir AC-IOIOOE / AC-IO100H
Portable
Air Conditioner
Owner's
Manual

Advertisement

loading

Summary of Contents for NewAir AC-10100E

  • Page 1 PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-IOIOOE / AC-IO100H Portable Air Conditioner Owner's Manual...
  • Page 2: General Safety

    For safety reasons, please read this manual carefully before operating. We strongly recommend keeping this manual in a safe place for future reference. GENERAL SAFETY Do not use a damaged power cord. Do not clamp or bend the power cord. Always operate the unit in an upright position and place it on a flat, level surface at least 14 inches away from any other object.
  • Page 3 ELECTRICAL SAFETY • This appliance is for indoor use only. • Always turn off the unit and unplug it when not in use. • Do not use this unit in excessively humid or wet environments. • Do not pull or place strain on the power cord when moving the appliance. •...
  • Page 4 Control panel Air outlet Carrying handle Caster Cord storage Air filter Air inlet Exhaust air outlet Air inlet 10. Rubber plug/drainage point 11. Hose adaptor (goes over the hose and into the window kit) 12, Exhaust hose _::::'..;. 13, Extendable window kit ii ii iiiiiiiiii iiiiiiiiiiiii i 14, Active carbon filter...
  • Page 5 window Open the window and insert the window kit into the open gap. Close the window until the window kit is held securely. You may need to adjust the size of the window kit and secure it with screws. This technique may also be used for sash windows.
  • Page 6 Mounting of the Exhaust Pipe Only use the hose provided clip exhaust hose to the back of the air conditioner. Avoid kinks and bends in the exhaust hose. This can cause moist air to accumulate, causing the unit to overheat and shut down.
  • Page 7 Installation of the Carbon Filter Remove the filter frame from the unit. Separate the filter fixer from the filter frame. Remove the activated carbon filter from its plastic bag. Attach the activated carbon filter to the filter frame. Reattach the filter fixer onto the filter frame (the activated carbon filter should...
  • Page 8 Control panel ® Automatic mode indicator ON/OFF (power) button Cooling mode indicator High fan speed indicator Fan (ventilation) mode indicator Low fan speed indicator Mode selection button Fan speed (ventilation) button Timer operation indicator Sleep mode indicator Timer button Sleep button Full water tank indicator Compressor indicator Temperature...
  • Page 9 Setting the Model/Function: Press the MODE button to select the desired mode (cooling, fan or heating). Setting Temperature Press 'Temperature up' or 'Temperature down' button to change the set temperature. The display window will indicate the set temperature. If not, the temperature displayed will show the ambient room temperature.
  • Page 10 Heating Function (For AC-10100H Only) When the air conditioner is in heating mode, ambient warm air is recycled and used to heat your immediate area. The exhaust pipe will still need to be fitted onto the unit in order for the cold air to be removed. Continuous drain is compulsory while the unit is in heat mode.
  • Page 11 During thecooling process, s omewaterwillbeextracted f romtheairandstored within the unit's waterreservoir. If thereservoir is full,boththecompressor andmotor willstopandtheunitwillbeep(press any button tostopthebeeping sound).Thefullwatertankindicator lightwillalsostartflashing. Toresume cooling, e mpty thereservoir b yfollowing thesesteps: Turn off the air conditioner and unplug it from the wall socket. To prevent water leakage, avoid moving the unit when full.
  • Page 12: Drain Tube

    Thedrain tubemaybeextended by adding anextension tubewitha suitable connector. Drain tube Please Note: The drain must be at or below the level Original drain tube of the drainage port. The full water tank indicator light will not work when the unit is being continuously drained.
  • Page 13 Always unplug the air conditioner from power supply before cleaning. maximize the efficiency of the air conditioner, regularly clean the unit. Cleaning the Housing: • Use a soft, damp cloth to wipe the body clean. • Never use aggressive chemicals, gasoline, detergents, chemically treated cloths, or other cleansing solutions.
  • Page 14 The air conditioner does not run. • Is the air conditioner plugged • Is the power outlet functioning correctly? • Is the full water tank indicator light flashing? • Is the ambient room temperature lower than the set temperature? unit does not produce enough Is the unit placed in direct sunlight?
  • Page 15 ModelNumber AC-10100E AC-10100H PowerConsumption 909W / 8.3A 909W / 8.3A (Cooling) Power Consumption 909W / 8.3A (Heating) Air Volume (Max. Speed) 218CFM (355m3/h) Dehumidification 2.11 pints/hour Capacity Power Supply 115V, 60Hz Compressor Type Rotary Refrigerant R-410A (Please refer to the rating label)
  • Page 16: Warranty

    Once confirmed that your appliance is eligible for warranty service, all repairs will be performed by a NewAir authorized repair facility. The purchaser will be responsible for any removal or transportation costs. Replacement parts and/or units will be new, re-manufactured...

This manual is also suitable for:

Ac-10100h