Warning!
Wear protective safety glasses when using compressed
air.
Caution:
8.
Slide the left side of the fuser assembly under the metal
bracket and lower into place.
9.
Tighten the two screws.
10.
Close the fuser cover assembly.

Transfer Roller Cleaning

1.
Turn off and unplug the printer.
2.
Remove the toner cartridge.
3.
Remove the roller assembly by turning up the roller's plastic
levers, one on each end (fig. 9.2); then, holding the levers, lift
the transfer roller up and out at a 45˚ angle.
_________________________
Do not pull out any wires while performing this
step.
Fig. 9.2 Transfer Roller