Installing the device in a rack or cabinet

CAUTION
Make sure the rack or cabinet housing the device is adequately secured to prevent it from
becoming unstable or falling over.
NOTE
You need a #2 Phillips screwdriver for installation.
Before mounting the switch in a rack, pay particular attention to the following factors:

2-Post rack mount installation

NOTE
Use the following procedure when installing the Brocade ICX 6650 device in a 2-post rack. For 4-post
racks, follow the procedures in the section
Remove the rack mount kit from the shipping carton. The kit contains the following:
FIGURE 7
Brocade ICX 6650 Hardware Installation Guide
53-1002599-02
Temperature: Since the temperature within a rack assembly may be higher than the ambient
room temperature, check that the rack-environment temperature is within the specified
operating temperature range. (Refer to
Mechanical loading: Do not place any equipment on top of a rack-mounted unit.
Circuit overloading: Be sure that the supply circuit to the rack assembly is not overloaded.
Grounding: Rack-mounted equipment should be properly grounded. Particular attention should
be given to supply connections other than direct connections to the mains.
Two L-shaped mounting brackets.
Sixteen 8-32 x 5/16 in., panhead Phillips screws with patchlocks.
Four 10-32 x 5/8 in., panhead Phillips screws (torque to 25 in-lb, 29 cm-kg). See item 1 in
Figure
7.
Eight 32-10 retainer nuts (for square-hole rack rails). See item 2 in
Eight 32-10 retainer nuts (for round-hole rack rails) See item 3 in
2-post screws and retainer nuts

Installing the device in a rack or cabinet

"Environmental considerations"
"4-Post rack mount installation"
2
on page 25.)
on page 31.
Figure
7.
Figure
7.
29