Standard Upgrade And Downgrade Procedures C; Procedure 8-Standard Downgrade, 2-Core Card Set - Cisco MGX 8220 Installation And Configuration Manual

Hide thumbs Also See for MGX 8220:
Table of Contents

Advertisement

Standard Upgrade and Downgrade Procedures
c.
Step 5
For all SMs, set the start and end addresses in Flash memory where the boot code file will be written.
a.
b.
c.
d.
For all SMs, perform the dsptotals command.
Step 6
Use this step to examine the number of lines, ports, and channels after the upgrade or downgrade. The
values can be compared to those before the download and, therefore, it can be established that the
configuration remained the same. Restore the ASC and SM configurations if necessary.
Procedure 8—Standard Downgrade, 2-Core Card Set
Procedure 8 is used for 1.4.y to 2.x, and 2.4.y to 3.x.
Step 1
Check compatibility.
With any downgrade technique, there is always the issue of compatibility. Any release can be
downgraded to any other release, but in many instances configuration information will be lost.
Hardware incompatibilities can prevent some downgrades. For example, Release 2 and Release 3
service modules require two Flash chips. Release 4 SMs will be shipped with a single Flash chip. A
Release 4 shelf containing BNM-E1 cards or service resource module 3T3 cards cannot be downgraded
to Release 2 or Release 3. Check the compatibility matrix to determine if a particular downgrade is
supported and how it affects configuration loss.
Step 2
Enter the dspadrcxat command. Note the value of the ConnNumOfValidEntries parameter.
This value indicates the number of connections. This command is run again at the end of the procedure
to ensure that the number of connections did not change.
For all stand-alone and primary SMs
Step 3
a.
a.
b.
Cisco MGX 8220 Installation and Configuration
C-14
Enter the version command. This command displays the version of the boot code currently stored
in Flash memory. This step downloads new firmware into the ASC.
Enter the flashStartAddr and flashEndAddr commands to start the Flash memory file at
0xbfc40000 and end it at 0xbfd00000
shelf.1.<slot>.<type><a|s>flashStartAddr = 0xbfc40000
shelf.1.<slot>.<type>.<a|s>flashEndAddr = 0xbfd0000
Enter the tftp put <SM_FW_file> AXIS_SM_1_$slot.BOOT command.
Enter the chkflash command. This command calculates and compares the Flash checksum to verify
whether the boot code is correct.
Enter the clrallcnf command. This command resets all cards on the shelf.
Enter the dsptotals command.
The configuration of the shelf should not be changed during the downgrade process. Use this step
to examine the number of lines, ports, and channels before the upgrade or downgrade. A similar
step can be made to examine the same configuration parameters after the upgrade or downgrade
and, therefore, it can be established that the configuration remained the same.
Enter the tftp put <ASC_BT_file> AXIS_ASC_BACKUP.FW command. This step downloads the
new boot code into the ASC.
Enter the chkflash command. This command calculates and compares the Flash checksum to verify
whether the boot code is correct.
Appendix C
Firmware Upgrade and Downgrade Procedures
Release 5.0, Part Number 78-6430-03 Rev. D0, November 2003

Advertisement

Table of Contents
loading

Table of Contents