Appendix C
Firmware Upgrade and Downgrade Procedures
d.
Enter the version command. This command displays the version of the boot code currently stored
in Flash memory. This step downloads new firmware into the ASC.
e.
Enter the switchcc command to switch to the other ASC.
f.
Enter the tftp put <ASC_BT_file> AXIS_ASC_BACKUP.FW command. This step downloads the
new boot code into the second ASC.
Enter the chkflash command. This command calculates and compares the Flash checksum to verify
g.
whether the boot code is correct.
Enter the version command. This command displays the version of the boot code currently stored
h.
in Flash memory. This step downloads new firmware into the ASC.
i.
Enter the tftp put <ASC_FW_file> AXIS_ASC_ACTIVE.FW command.
j.
Check the file size of the downloaded firmware. Use this step to check that the firmware was
downloaded successfully to the ASC disk.
k.
Enter the dspfwrevs command to verify the correct firmware revision.
Enter the tftp put <ASC_FW_file> AXIS_ASC_STANDBY.FW command.
l.
Check the file size of the downloaded firmware. Use this step to check that the firmware was
m.
downloaded successfully to the ASC disk.
Enter the dspfwrevs command to verify the correct firmware revision.
n.
For all SMs, set the start and end addresses in Flash memory where the boot code file will be written.
Step 4
Enter the flashStartAddr and flashEndAddr commands to start the Flash memory file at
a.
Oxbfc00000 and end it at 0xbfc40000
shelf.1.<slot>.<type><a|s>flashStartAddr = 0xbfc00000
shelf.1.<slot>.<type>.<a|s>flashEndAddr = 0xbfc40000
Enter the tftp put <SM_BT_file> AXIS_SM_1_$slot.FW command.
b.
c.
Enter the chkflash command. This command calculates and compares the Flash checksum to verify
whether the boot code is correct.
d.
Enter the version command. This command displays the version of the boot code currently stored
in Flash memory. This step downloads new firmware into the ASC.
For all SMs, set the start and end addresses in Flash memory where the firmware file will be written.
Step 5
Enter the flashStartAddr and flashEndAddr commands to start the Flash memory file at
a.
Oxbfc40000 and end it at 0xbfd00000
shelf.1.<slot>.<type><a|s>flashStartAddr = 0xbfc40000
shelf.1.<slot>.<type>.<a|s>flashEndAddr = 0xbfd00000
Enter the tftp put <SM_FW_file> AXIS_SM_1_$slot.FW command.
b.
c.
Enter the chkflash command. This command calculates and compares the Flash checksum to verify
whether the boot code is correct.
d.
Enter the resetsys or clrallcnf command. These commands reset all cards on the shelf.
Set the BRAM revision.
e.
f.
Enter the dspadrxlat command to ensure that the number of connections is correct.
Step 6
Enter the dsptotals command for all primary and stand-alone SMs.
Release 5.0, Part Number 78-6430-03 Rev. D0, November 2003
Standard Upgrade and Downgrade Procedures
Cisco MGX 8220 Installation and Configuration
C-9