Table 8-6
Error Number
6261
6271
6281
6282
6283
6284
6285
6286
6288
6289
6290
6292
6293
6294
6295
Replacing Parts
After an alarm occurs, use the MGX 8220 shelf software to isolate the problem. If an MGX 8220 shelf
part has failed, it must be replaced.
Caution
Only authorized personnel should remove and replace parts on the MGX 8220 system.
Cisco MGX 8220 Installation and Configuration
8-20
AUSM Log Codes (continued)
Display Log String
Foresight Enable Failed
PLPP FIFO Overrun
Failed to Add Egress Q
Failed to modify Egress Q
Failed to delete Egress Q
BERT error
AUSM out of xmt buffer
Invalid value
Undoing delete with add line
failed
Undoing add with delete line
failed
Undoing modify with
modify line failed
Undoing delete with add
port failed
Undoing add with delete
port failed
Undoing modify with
modify port failed
Updating BNM failed
Replacing a Front Card, page 8-21
Replacing a Back Card, page 8-21
Replacing a DC Power Entry Module, page 8-22
Replacing the Cooling, Booster, Plenum, and AC Power Assemblies, page 8-23
Detail Description
Failed to start Fore Sight interrupt service routine.
PLPP FIFO overflow has occurred.
Failed to add egress queue to specified port.
Failed to modify egress queue parameters.
Deletion of egress queue failed.
Error in BERT. Details on the specific instance of
BERT failure is displayed.
AUSM card is out of buffers, malloc failed.
Invalid value for parameters. Additional information
on the specific parameter is displayed.
Failed while trying to undo delete line (by adding the
line back). Trying to undo because of ASC MIB
update failure.
Failed while trying to undo add line (by deleting the
line). Trying to undo because of ASC MIB update
failure.
Failed while trying to undo modify line. Trying to
undo because of ASC MIB update failure.
Failed while trying to undo delete port (by adding the
port back). Trying to undo because of ASC MIB
update failure.
Failed while trying to undo add port (by deleting the
port). Trying to undo because of ASC MIB update
failure.
Failed while trying to undo modify port. Trying to
undo because of ASC MIB update failure.
Failed to update BNM. Addtional information
describing the specific instance of failure is
displayed.