Table 2-4 Srm-T1/E1 Led Indicators - Cisco MGX 8220 Installation And Configuration Manual

Hide thumbs Also See for MGX 8220:
Table of Contents

Advertisement

Core Module Overview
SRM-T1/E1 LED Indicators
All LEDs are located on the faceplate of the front card. The SRM-T1/E1 LED indicators are described
in Table 2-4.
Table 2-4
Type of LED
ACT
STBY
FAIL
1:N RED
BERT
AX-SRM-3T3
The SRM-3T3 service redundancy module provides bulk distribution of T1 circuits to the 4-port or
8-port T1 service modules. Rather than individually cable each of the 40 or 80 incoming T1/E1 lines to
an MGX 8220 edge concentrator, the MGX 8220 backplane is designed with a distribution bus that
allows an AX-SRM-3T3 to distribute T1s received "in bulk" to T1-based service modules. This
eliminates the need for T1 back cards for each service module and the associated cabling and potential
overloading of the digital cross-connect system port. The AX-SRM-3T3 provides a method to bring in
from one to three T3 interfaces that can be demultiplexed to their constituent T1s, providing up to 28,
56, or 80 T1s to be distributed to T1 service modules over the distribution bus. Both 4-port and 8-port
service modules are supported in any combination. The AX-SRM-3T3 supports the following features:
Out of the maximum possible 84 T1 channels (3 times 28), up to 80 channels can be active at any time.
Any T1 channel in a T3 line can be distributed to any four/eight port on a service module in any slots
5 to 14 without restriction.
The AX-SRM-3T3 can also be operated in "nonbulk mode" on a port-by-port basis. For a port
configured in nonbulk mode, bulk distribution is disabled and the SRM acts as a AX-SRM-T1/E1
providing BERT and 1:N redundancy functions only.
Figure 2-18 shows an illustration of the AX-SRM-3T3 cards.
Cisco MGX 8220 Installation and Configuration
2-24
SRM-T1/E1 LED Indicators
Color
Green
Yellow
Red
Green
Green
1:1 redundancy of the SRM with Y-cabling.
The same features as the AX-SRM-T1E1, including bit rate error test (BERT) and 1:N redundancy
of T1/E1 service modules.
Spare service module that can be used to provide redundancy for both bulk-distributed and
line-module-based service modules concurrently (a redundancy back card will be required for a
spare service module providing redundancy for line module-based service modules).
No back card required for T1 service modules that use bulk distribution.
Mix of service modules using bulk distribution with service modules using line modules in the
same shelf.
Mix of 4-port and 8-port cards, with all 10 slots always available to service modules via either line
modules or bulk.
Meaning
On indicates the card set is in active mode.
On indicates the card set is in standby mode.
On indicates the BNM-155 card set has failed or the line module
is missing.
On indicates 1:N redundancy has been invoked.
Off indicates 1:N redundancy is not active.
On indicates the BERT function is active.
Release 5.0, Part Number 78-6430-03 Rev. D0, November 2003
Chapter

Advertisement

Table of Contents
loading

Table of Contents