589A042-060 With Optional Base Rail, Unit Dimensions - Bryant 588A Installation, Start-Up And Service Instructions Manual

Single package gas heating/ electric cooling units
Hide thumbs Also See for 588A:
Table of Contents

Advertisement

UNIT
ELECTRICAL
589A
CHARACTERISTICS
042060/080
208/230-1-60, 208/230-3-60, 460-3-60
042100/120
208/230-1-60, 208/230-3-60, 460-3-60
048080
208/230-1-60, 208/230-3-60, 460-3-60
048100/120/140
208/230-1-60, 208/230-3-60, 460-3-60
060080
208/230-1-60, 208/230-3-60
060100/120/140
208/230-1-60, 208/230-3-60
CENTER OF GRAVITY (in./mm)
UNIT
589A
X
042060/080
26.55/674.4
042100/120
26.50/673.0
048080
28.25/717.6
048100/120/140
28.16/715.3
060080
28.18/715.6
060100/120/140
27.79/705.9
CG
COND
LV
MAT'L — Material
NEC
REQ'D — Required
UNIT WEIGHT
lb
415
427
446
458
477
489
Y
Z
21.22/539.0
17.66/448.6
21.24/539.6
17.66/448.6
20.04/509.0
17.66/448.6
20.08/510.0
17.66/448.6
20.19/512.8
17.66/448.6
20.23/513.8
17.66/448.6
Fig. 9 — 589A042-060 With Optional Base Rail, Unit Dimensions
REQ'D CLEARANCES FOR SERVICING. in. (mm)
Duct panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
Unit top . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 (914)
Side opposite ducts
. . . . . . . . . . . . . . . . . . . . . 36 (914)
Compressor access
. . . . . . . . . . . . . . . . . . . . . 36 (914)
(Except for NEC requirements)
REQ'D CLEARANCES TO COMBUSTIBLE MAT'L. in. (mm)
Maximum extension of overhangs . . . . . . . . . . . . . . . 48 (1219)
Unit top . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 (356)
Duct side of unit . . . . . . . . . . . . . . . . . . . . . . . . 2 (51)
Side opposite ducts
. . . . . . . . . . . . . . . . . . . . . 14 (356)
Bottom of unit . . . . . . . . . . . . . . . . . . . . . . . . . . . 0
Flue panel
. . . . . . . . . . . . . . . . . . . . . . . . . 36 (914)
LEGEND
— Center of Gravity
— Condenser
— Low Voltage
— National Electrical Code
CORNER WEIGHT
(lb/kg)
kg
A
B
189
106/48
97/44
194
109/50
100/45
293
115/52
91/41
208
118/54
94/43
217
123/56
99/45
222
126/57
102/46
NOTES:
1. Clearances must be maintained to prevent recirculation of air from outdoor-
fan discharge.
2. Adequate clearance around air openings into combustion chamber must be
provided.
NEC REQ'D CLEARANCES. in. (mm)
Between units, control box side . . . . . . . . . . . . . . . . 42 (1067)
Unit and ungrounded surfaces, control box side . . . . . . . . . 36 (914)
Unit and block or concrete walls and other grounded
surfaces, control box side . . . . . . . . . . . . . . . . . . 42 (1067)
—9—
C
D
126/57
86/39
129/59
89/40
164/75
76/35
167/76
79/36
173/79
82/37
173/79
88/40