Required Suction-Tube Temperature (F) - Bryant 588A Installation, Start-Up And Service Instructions Manual

Single package gas heating/ electric cooling units
Hide thumbs Also See for 588A:
Table of Contents

Advertisement

SUPERHEAT
TEMP (F)
61.5
0
35
2
37
4
39
6
41
8
43
10
45
12
47
14
49
16
51
18
53
20
55
22
57
24
59
26
61
28
63
30
65
32
67
34
69
36
71
38
73
40
75
*Temperature at suction service valve.
Table 11 — Dry-Coil Air Delivery* — Horizontal Discharge at 230 and 460 V — Unit 588A
UNIT
MOTOR
AIR
588A
SPEED
DELIVERY
Watts
Low
Cfm
018
Watts
High
Cfm
Watts
Low
Cfm
Watts
024,
Med
030
Cfm
Watts
High
Cfm
Watts
Low
Cfm
Watts
036
Med
Cfm
Watts
High
Cfm
Watts
Low
Cfm
042
Watts
High
Cfm
Watts
Low
Cfm
048
Watts
High
Cfm
Watts
Low
Cfm
Watts
060
Med
Cfm
Watts
High
Cfm
*Air delivery values are without air filter and are for dry coil. See
Table 17 for wet coil pressure drop. Deduct field-supplied air filter pres-
sure drop and wet coil pressure drop to obtain external static pressure
available for ducting.
†Unit air delivery is outside of operating range.
Table 10 — Required Suction-Tube Temperature (F)*
SUCTION PRESSURE AT SERVICE PORT (psig)
64.2
67.1
70.0
37
39
41
39
41
43
41
43
45
43
45
47
45
47
49
47
49
51
49
51
53
51
53
55
53
55
57
55
57
59
57
59
61
59
61
63
61
63
65
63
65
67
65
67
69
67
69
71
69
71
73
71
73
75
73
75
77
75
77
79
77
79
81
(Deduct 10% from Cfm and Watts for 208 V Operation)
0.0
0.1
0.2
230
225
220
760
745
725
275
275
273
857
835
802
371
368
360
1079
1063
1027
514
493
476
1409
1383
1324
473
447
427
1253
1253
1172
519
500
478
1414
1366
1287
667
634
609
1734
1639
1563
678
635
604
1540
1515
1475
820
785
1825
1750
854
2026
1104
1093
1072
1876
1865
1840
1351
1295
1245
2249
2209
2157
1391
2299
—41—
73.0
76.0
43
45
45
47
47
49
49
51
51
53
53
55
55
57
57
59
59
61
61
63
63
65
65
67
67
69
69
71
71
73
73
75
75
77
77
79
79
81
81
83
83
85
EXTERNAL STATIC PRESSURE (in. wg)
0.3
0.4
0.5
210
195
170
695
640
540
270
235
850
700
269
260
257
782
745
717
349
345
326
996
978
919
460
443
425
1282
1223
1156
1068
418
395
367
1130
1047
946
459
439
410
1234
1162
1074
593
564
541
1461
1370
1292
1157
580
550
520
1430
1375
1280
1225
750
700
680
1685
1610
1525
1485
786
744
706
1905
1830
1752
1603
905
846
824
2025
1905
1830
1752
1029
986
938
1803
1765
1710
1641
1197
1148
1096
1053
2097
2036
1959
1882
1343
1296
1247
1191
2231
2152
2060
1975
NOTE: Do not operate the unit at a cooling airflow that is less than
350 cfm for each 12,000 Btuh of rated cooling capacity. Evaporator-coil
icing may occur at airflows below this point. Water blow-off may occur at
airflows above 450 cfm per 12,000 Btuh of rated cooling
capacity.
79.2
82.4
47
49
49
51
51
53
53
55
55
57
57
59
59
61
61
63
63
65
65
67
67
69
69
71
71
73
73
75
75
77
77
79
79
81
81
83
83
85
85
87
87
89
0.6
0.7
0.8
0.9
200
450
249
663
319
304
293
865
783
726
401
378
344
984
857
346
337
323
865
829
768
377
357
340
920
829
743
506
469
436
422
960
829
743
493
455
430
1128
1020
649
612
570
1355
1215
641
606
557
511
1513
1367
1228
804
748
683
637
1603
1398
1228
891
830
769
733
1533
1425
1345
994
936
871
1781
1679
1542
1129
1067
1002
1859
1746
1591
85.7
51
53
55
57
59
61
63
65
67
69
71
73
75
77
79
81
83
85
87
89
91
1.0
697
1264
812
1405
936
1441