Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Bryant Manuals
Air Conditioner
588A
Installation, start-up and service instructions manual
Table Of Contents - Bryant 588A Installation, Start-Up And Service Instructions Manual
Single package gas heating/ electric cooling units
Hide thumbs
Also See for 588A
:
User manual
(27 pages)
,
Manual
(28 pages)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
Table Of Contents
53
page
of
53
Go
/
53
Contents
Table of Contents
Troubleshooting
Bookmarks
Table of Contents
Advertisement
Table of Contents
Unit 589A Shown With Optional Base Rail
1
General
1
Safety Considerations
1
Table Of Contents
1
588A018-042 Without Base Rail, Unit Dimensions
2
Rear View
2
Left Side View
2
Front View
2
588A018-042 With Optional Base Rail, Unit Dimensions
3
588A048,060 Without Base Rail, Unit Dimensions
4
588A048,060 With Optional Base Rail, Unit Dimensions
5
589A024-036 Without Base Rail, Unit Dimensions
6
589A024-036 With Optional Base Rail, Unit Dimension
7
589A042-060 Without Base Rail, Unit Dimensions
8
589A042-060 With Optional Base Rail, Unit Dimensions
9
Receiving And Installation
10
Step 1 - Check Equipment
10
Step 2 - Provide Unit Support
10
Step 3 - Field Fabricate Ductwork
10
Step 4 - Provide Clearances
10
Step 5 - Rig And Place Unit
10
Roof Curb Dimensions
11
Slab Mounting Details
12
Notice To Riggers
12
Suggested Rigging For Units Without Base Rail
12
Suggested Rigging For Units With Optional Base Rail
12
Condensate Trap
13
Step 6 - Connect Condensate Drain
13
Step 7 - Install Flue Hood
13
Step 8 - Install Gas Piping
13
Physical Data — Unit 588A
14
Physical Data — Unit 589A
15
Configuring Units For Downflow (Vertical) Discharge
16
Sediment Trap
16
Step 9 - Install Duct Connections
16
Maximum Gas Flow Capacity
17
Supply And Return Duct Openings
17
Vertical Duct Cover Removed
17
Lance Location For Vertical Duct Opening Cover
17
Vertical Discharge Cover Removed
18
High-Voltage Connections
18
Standard Power Entry
18
Step 10 - Install Electrical Connections
18
Electrical Data — Unit 588A
19
Legend
19
Electrical Data — Unit 589A
20
High- And Control-Voltage Connections
21
Alternate Power Entry
21
Standard Connection
21
Alternate Connection
21
Pre-Start-Up
22
Easy Select Interface Board
22
Heat Anticipator Setting
22
Transformer Protection
22
Check For Refrigerant Leaks
23
Start Up Heating Section And Make Adjustments
23
Check Gas Input
23
Adjust Gas Input
23
Measure Gas Flow (Natural Gas Units)
24
Burner Assembly
24
Rated Gas Inputs At Indicated Manifold Pressures
24
Measure Manifold Pressure (Propane Units)
25
Check Burner Flame
25
Monoport Burners
25
Air Delivery (Cfm) At Indicated Temperature Rise /Rated Heating Input
25
Heating Sequence Of Operation
26
Start Up Cooling Section And Make Adjustments
26
Led Indications
26
Checking Cooling Control Operation
26
208/230-1-60 Wiring Diagram, Units 588A018-060
27
208/230-3-60 Wiring Diagram, Units 588A030-060
28
460-3-60 Wiring Diagram, Units 588A036-060
29
208/230-1-60 Wiring Diagram, Units 589A024-042
30
208/230-1-60 Wiring Diagram, Units 589A048,060
31
208/230-3-60 Wiring Diagram, Units 589A036-042
32
208/230-3-60 Wiring Diagram, Units 589A048,060
33
460-3-60 Wiring Diagram, Units 589A036-048
34
Indoor Airflow And Airflow Adjustments
35
Checking And Adjusting Refrigerant Charge
35
For Integrated Control Motors (Icm)
36
Superheat Charging Table, 588A018
36
Superheat Charging Table, 588A024
36
Superheat Charging Table, 588A030
37
Superheat Charging Table, 588A036
37
Superheat Charging Table, 588A042
37
Superheat Charging Table, 588A048 (Carrier Scroll Compressor)
38
Superheat Charging Table, 588A048 (Copeland Scroll Compressor)
38
Superheat Charging Table, 588A060
38
Superheat Charging Table, 589A024
39
Superheat Charging Table, 589A030
39
Superheat Charging Table, 589A036
39
Superheat Charging Table, 589A042
40
Superheat Charging Table, 589A048
40
Superheat Charging Table, 589A060
40
Required Suction-Tube Temperature (F)
41
Dry-Coil Air Delivery
42
Maintenance
44
Wet Coil Pressure Drop
44
Cooling Sequence Of Operation
44
Air Filter
45
Unit Top Removal
45
Evaporator Blower And Motor
45
Flue Gas Passageways
45
Combustion-Air Blower
46
Limit Switch
46
Burner Ignition
46
Main Burners
46
Condenser Coil, Evaporator Coil, And Condensate Drain Pan
47
Electrical Controls And Wiring
47
Refrigerant Circuit
47
Gas Input
47
Evaporator Airflow
47
Metering Device - Acutrol™ Device
47
Liquid Line Strainer
47
Troubleshooting
48
Cooling
48
Led Troubleshooting — Error Code
50
Service Training
50
Start-Up Checklist
52
Previous
Page
1
...
50
51
52
53
Show Quick Links
Quick Links:
General
Table of Contents
Electrical Controls and Wiring
Troubleshooting
Hide quick links:
Permanently
Temporary
Cancel
Advertisement
Table of Contents
Troubleshooting
Troubleshooting
48
LED Troubleshooting — Error Code
50
Related Manuals for Bryant 588A
Air Conditioner Bryant 588A Manual
Single package gas heating/ electric cooling units (28 pages)
Air Conditioner Bryant 588A User Manual
Single package gas heating/ electric cooling units (27 pages)
Air Conditioner Bryant 580J*08--14D Service And Maintenance Instructions
(2-compressor) nominal 7.5 to 12.5 tons with puron (r-410a) refrigerant (85 pages)
Air Conditioner Bryant 579D User Manual
Gas heating/electric cooling rooftop units (17 pages)
Air Conditioner Bryant 585B/YACR Installation, Operating And Maintenance Instructions
Packaged gas heating/electric cooling unit (16 pages)
Air Conditioner Bryant COMMERCIAL SINGLE PACKAGE ROOFTOP GAS HEAT/ELECTRIC COOLING 581B User Manual
Durapac plus series sizes 036-150 commercial single package rooftop gas heat/electric cooling units (65 pages)
Air Conditioner Bryant 580D Product Information Manual
Commercial single package rooftop gas heating/electric cooling units 3 to 25 tons (73 pages)
Air Conditioner Bryant 580J***(D Submittal Data
Single package rooftop gas heating/electric cooling unit two stage cooling capacity control with novation coil sizes 08, 12, 14 with puron (r--410a) refrigerant (8 pages)
Air Conditioner Bryant 581A/B Product Information Manual
Durapac and durapac plus series commercial single package rooftop units gas heating/electric cooling units (268 pages)
Air Conditioner Bryant 581J Installation Instructions Manual
Single package rooftop gas heating/electric cooling unit sizes 07, 08, 09 & 12 with puron (r--410a) refirgerant (40 pages)
Air Conditioner Bryant 582K Installation Instructions Manual
3 to 12.5 tons (48/50lc 14 not included) accessory ultra low leak vertical economiser x (24 pages)
Air Conditioner Bryant LEGACY 580J Product Data
Gas heat/electric cooling packaged rooftop 3 to 15 nominal tons (95 pages)
Air Conditioner Bryant 580J Submittal Data
Single package rooftop gas heating/electric cooling horizontal air flow units, with puron (r-410a) refrigerant 15, 17.5, 20, 25 tons (model sizes 18, 21, 25, 29) (14 pages)
Air Conditioner Bryant 581J Series Manual
High-efficiency gas heat/electric cooling packaged rooftop (68 pages)
Air Conditioner Bryant Legacy Series Installation Instructions Manual
Single package rooftop gas heat/electric cooling unit with puron (r-410a) refrigerant (44 pages)
Air Conditioner Bryant 581J-17-28 Service And Maintenance Instructions
Gas heat rooftop package nominal 15 to 25 tons with puron (r-410a) refrigerant (84 pages)
Related Content for Bryant 588A
R-22 Table Of Contents Safety Considerations
Bryant R-22
189BNV EVOLUTION Fault Code Action Table
Bryant 189BNV EVOLUTION
538PAQ012RBMA Table Of Contents
Bryant 538PAQ012RBMA
574D----A Table Of Contents
Bryant 574D----A
580D Table Of Contents
Bryant 580D
PREFERRED 581J Table Of Contents
Bryant PREFERRED 581J
LEGACY 580J Table Of Contents
Bryant LEGACY 580J
This manual is also suitable for:
589a
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL