Sign In
Upload
Manuals
Brands
Bryant Manuals
Air Conditioner
LEGACY 580J
Bryant LEGACY 580J Manuals
Manuals and User Guides for Bryant LEGACY 580J. We have
7
Bryant LEGACY 580J manuals available for free PDF download: Product Data, Installation, Start-Up And Service Instructions Manual, Installation Instructions Manual, Manual, Submittal Data
Bryant LEGACY 580J Product Data (95 pages)
GAS HEAT/ELECTRIC COOLING PACKAGED ROOFTOP 3 TO 15 NOMINAL TONS
Brand:
Bryant
| Category:
Air Conditioner
| Size: 5 MB
Table of Contents
Product Data
1
Table of Contents
2
Easy to Install
2
Easy to Maintain
2
Easy to Use
2
Features and Benefits
3
Model Number Nomenclature
4
Factory - Installed Options and Field - Installed Accessories
5
Factory Options And/Or Accessories
6
AHRI Cooling Rating Table
8
Heating Rating Table - Natural Gas & Propane
9
Heating Rating Table - Low no
10
Sound Performance Table
10
Minimum - Maximum Airflow Ratings - Natural Gas & Propane
11
Cooling
12
Physical Data
12
Heating
13
Curbs & Weights Dimensions - 580J04-07
18
Curbs & Weights Dimensions - 580J 08-12
21
Service Clearance
22
Curbs & Weights Dimensions - 580J 08-14
23
Roof Curb Details
23
Curbs & Weights Dimensions - 580J 14
24
Curbs & Weights Dimensions - 580J 16
26
Options & Accessory Weights
29
Application Data
30
Selection Procedure (with 580J*07A Example)
32
Cooling Capacities
33
Stage Cooling
33
Cooling Tables
33
Perfect Humidity
53
Economizer, Barometric Relief and PE Performance
53
Static Pressure Adders
53
General Fan Performance Notes
55
580J**04
56
Fan Performance
56
580J**05
58
580J**06
60
580J**07
62
580J**08
63
580J**09
64
580J**12
65
580J**14
66
580J*16
67
580J**16
67
Pulley Adjustment
68
580J*06A
69
580J*05A
69
580J*04A
69
Electrical Information
69
580J*07A
70
580J*08A
70
580J*08D
70
580J*09A
71
580J*09D
71
580J*12A
71
580J*16D
72
580J*14D
72
580J*12D
72
MCA/MOCP Determination no C.O. or UNPWRD C.O.
73
MCA/MOCP Determination W/ PWRD C.O.
75
Stage Cooling Typical Power Diagram
77
Typical Wiring Diagrams
77
General
81
Electromechanical Units with no Economizer
81
Electromechanical Units with an Economizer
81
Sequence of Operation
81
Reheat2 (Hot Gas Reheat Mode) - - 580J04- -16
82
Normal Cooling
82
Optional Perfect Humidity System
82
Reheat1 (Subcooling Mode) - - 580J04- -16
82
Subcooling Mode (Reheat 1) - - Perfect Humidity System (580J04- -16)
83
Hot Gas Reheat Mode (Reheat2) - - Perfect Humidity System (580J04- -16)
83
Guide Specifications - 580J**04-16
84
Gas Heat/Electric Cooling Packaged Rooftop
84
HVAC Guide Specifications
84
Advertisement
Bryant LEGACY 580J Installation, Start-Up And Service Instructions Manual (64 pages)
Variable Frequency Drive (VFD) Factory-Installed Option 2-Speed Motor Control for 2-Stage Cooling Rooftop Units
Brand:
Bryant
| Category:
Air Conditioner
| Size: 12 MB
Table of Contents
Table of Contents
1
Safety Considerations
1
General
2
2-Speed Indoor Fan Motor Indoor Fan Speed System
2
Identifying Factory Option
2
Unit Installation with 2-Speed Indoor Fan Motor Option
2
Pre-Start Check, 2-Speed Indoor Fan Motor Option
5
Start-Up, 2-Speed Indoor
16
Fan Motor Option
16
Compressor Rotation
16
Indoor Fan Motor
16
Cooling with 2-Speed Indoor Fan Motor
16
Operating Sequences, 2-Speed Indoor Fan Motor Option
16
Cooling (FAN Switch in AUTO)
16
Heating
17
Operating Fan for Test and Balance
17
Service
18
2-Speed Indoor Fan Motor Option Components
18
Fan Speed Relay Board
18
Configuration Jumpers
18
Variable Frequency Drive
18
Central Terminal Board Jumpers (548J/549J/551J/558J/580J/581J Series Only)
20
VFD Fuses
21
Control and Power Wiring Diagrams
22
Vfd Alarms and Faults Troubleshooting
29
Alarms
29
Faults
29
Vfd Maintenance
30
Heat Sink Cleaning
30
Fan Replacement
31
Bypass the VFD
33
Vfd Parameters
34
Vfd Remote Keypad
45
ACH550/ACS320 Operation with Remote Keypad
45
ACH550/ACS320 VFD Modes
45
ACH550/ACS320 VFD Diagnostics
47
Correcting Faults
47
History
47
Reset after Using Start-Up Assistant
50
ACH580 Operation with Remote Keypad
51
ACH580 VFD Modes
52
ACH580 VFD Diagnostics
54
All Ach580, Ach550 and Acs320 Keypads
57
Control Panel Cleaning
57
Battery Replacement
57
VFD Remote Keypad Parameters
57
Bryant LEGACY 580J Installation Instructions Manual (56 pages)
Single Package Rooftop with Gas Heat/Electric Cooling Vertical Air Flow Unit with Puron (R-410A) Refrigerant
Brand:
Bryant
| Category:
Heat Pump
| Size: 9 MB
Table of Contents
Table of Contents
1
Safety Considerations
1
Installation Instructions
1
General
2
Installation
10
Job-Site Survey
10
Step 1 - Plan for Unit Location
10
Step 2 - Plan for Sequence of Unit Installation
11
Step 3 - Inspect Unit
11
Step 4 - Provide Unit Support
11
Step 5 - Field Fabricate Ductwork
16
Step 6 - Rig and Place Unit
16
Step 7 - Install Outside Air Hood
17
Step 8 - Install Flue Hood and Combustion Air Hood
17
Step 9 - Install Gas Piping
18
Step 10 - Install External Condensate Trap and Line
20
Step 11 - Make Electrical Connections
20
Outdoor Air Enthalpy Control
48
Step 12 - Adjust Factory-Installed Options
53
Step 13 - Install Accessories
53
Step 14 - Check Belt Tension
53
Pre-Start and Start-Up
54
Ii580J
54
Start-Up Checklist
55
Advertisement
Bryant LEGACY 580J Installation Instructions Manual (24 pages)
3 to 12.5 Tons (48/50LC 14 Not Included) Accessory Ultra Low Leak Vertical EconoMiser X
Brand:
Bryant
| Category:
Air Conditioner
| Size: 2 MB
Table of Contents
Table of Contents
1
Safety Considerations
1
General
2
Accessories List
3
Compliance
3
Installation
4
Instructions for 48/50LC 07-12 Units Only
9
Installing Optional HH57AC081 Single Outside Air
13
Enthalpy Sensor
13
Installing Differential Return Air Sensor
14
California's Title 24 High Temperature Limit
14
Settings
14
Demand Controlled Ventilation (DCV)
14
Remote (Downstairs) Monitoring of Controller's Fault Detection and Diagnostics
15
General W7220 Controller and Sensor Information
16
W7220 Economizer
16
User Interface
16
Keypad
16
Using the Keypad with Menus
16
Using the Keypad with Settings and Parameters
16
Menu Structure
16
Programming W7220 Controller
16
Setpoints
16
System Setup
17
Checkout Tests
21
W7220 Economizer Module Wiring
22
Time-Out and Screen Saver
22
Start-Up and Operation
22
Cooling, Unit with Economi$Er® X
22
Heating with Economi$Er® X
22
Troubleshooting
24
Power Loss (Outage or Brownout)
24
Alarms
24
Clearing Alarms
24
Bryant LEGACY 580J Manual (25 pages)
Rooftop Units 3 to 27.5 Nominal Tons
Brand:
Bryant
| Category:
Air Conditioner
| Size: 1 MB
Table of Contents
Electro- -Mechanical Controls
3
Safety Considerations
6
Electrical Shock Hazard
6
Cut Hazard
6
Specifications
8
Before Installation
8
Installation and Setup
9
Economizer Module Wiring Details
9
W7220 Economizer Module Wiring
9
CO 2 Sensor Wiring
10
Interface Overview
10
Menu Structure
11
Setup and Configuration
11
Sequence of Operation
17
Enthalpy Settings
21
Two- - Speed Fan Operation
21
Initial Menu Display
22
Troubleshooting
23
Clearing Alarms
23
Bryant LEGACY 580J Submittal Data (8 pages)
SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNIT SIZES 04-07 with PURON (R-410A) REFRIGERANT
Brand:
Bryant
| Category:
Air Conditioner
| Size: 0 MB
Table of Contents
Standard Features
1
Description
1
Performance Data
2
Electrical Data
2
STANDARD FEATURES (Cont.)
2
Gas Heat
2
Standard Parts Warranty
2
Submittal Data
2
FACTORY-INSTALLED OPTIONS (Fiops)
3
Optional Warranties
3
Field Installed Accessories
4
Roof Curb Details
7
Bryant LEGACY 580J Submittal Data (14 pages)
SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING HORIZONTAL AIR FLOW UNITS, WITH PURON (R-410A) REFRIGERANT 15, 17.5, 20, 25 TONS (MODEL SIZES 18, 21, 25, 29)
Brand:
Bryant
| Category:
Air Conditioner
| Size: 3 MB
Table of Contents
Standard Features
1
Performance Data
2
Electrical Data
2
Field Installed Accessories
4
Advertisement
Related Products
Bryant 580J*08--14D
Bryant 580J*04--12
Bryant 580J***D series
Bryant 580J*08-14F
Bryant 580J*04A
Bryant 580J*04B
Bryant 580J*05C
Bryant 580J*06A
Bryant 580J*04C
Bryant 580J*06B
Bryant Categories
Air Conditioner
Furnace
Heat Pump
Thermostat
Fan
More Bryant Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL