Sign In
Upload
Manuals
Brands
Bryant Manuals
Air Conditioner
581J
Bryant 581J Manuals
Manuals and User Guides for Bryant 581J. We have
5
Bryant 581J manuals available for free PDF download: Product Data, Installation, Start-Up And Service Instructions Manual, Installation Instructions Manual, Manual
Bryant 581J Product Data (67 pages)
Preferred Series GAS HEAT/ELECTRIC COOLING PACKAGED ROOFTOP 3 to 8.5 NOMINAL TONS
Brand:
Bryant
| Category:
Air Conditioner
| Size: 3 MB
Table of Contents
Product Data
1
Easy to Use
2
Table of Contents
2
Easy to Maintain
2
Easy to Install
2
Features and Benefits
3
Model Number Nomenclature
4
Factory-Installed Options and Field-Installed Accessories
5
Economizer
6
Power Exhaust with Barometric Relief
6
Time Guard II Control Circuit
6
Factory Options And/Or Accessories
6
Motormaster Head Pressure Controller
7
Winter Start Kit
7
Propane Heating
7
High Altitude Heating
7
Ahri Cooling Rating Tables
8
Heating Rating Table
9
Sound Performance Table
10
Physical Data
12
Curbs & Weights Dimensions
16
Service Clearance
17
Min Operating Ambient Temp (Cooling)
23
Max Operating Ambient Temp (Cooling)
23
Min Mixed Air Temp (Heating)
23
Application Data
23
Sizing a Rooftop
24
Low Ambient Applications
24
Select Factory Options
25
Make an Initial Guess at Cooling Tons
25
Determine Cooling and Heating Loads
25
Selection Procedure
25
Cooling Capacities
26
Stage Cooling
26
Cooling Tables
26
General Fan Performance Notes
32
Static Pressure Adders
32
Fan Performance
33
Return Air Pressure Drop
43
Vertical Power Exhaust Performance
43
Barometric Relief Flow Capacity
43
Economizer, Barometric Relief and Pe Performance
43
Outdoor Air Intake & Exhaust Perf
43
Electrical Information
44
Mca/Mocp
46
1-Stage Cooling Typical Power Diagram
51
Typical Wiring Diagrams
51
2- -Stage Cooling Typical Power Diagram
52
Cooling
55
Heating
55
Sequence of Operation
55
Gas Heat/Electric Cooling Packaged Rooftop
57
HVAC Guide Specifications
57
Guide Specifications
57
Electric and Electronic Control System for HVAC
58
Sequence of Operations for HVAC Controls
59
Panel Air Filters
59
Self- - Contained Air Conditioners
59
Electrical Requirements
60
Unit Cabinet
60
Operating Characteristics
60
Project Conditions
60
Gas Heat
61
Optional Stainless Steel Heat Exchanger Construction
61
Standard Heat Exchanger Construction
61
Induced Draft Combustion Motor and Blower
61
Coils
62
Standard Aluminum Fin/Copper Tube Coils
62
Refrigerant Components
62
Condenser Fans and Motors
63
Evaporator Fan and Motor
63
Filter Section
63
Compressors
63
Two-Position Damper
64
Manual Damper
64
Head Pressure Control Package
64
Propane Conversion Kit
64
Powered Convenience Outlet
65
Flue Discharge Deflector
65
Propeller Power Exhaust
65
Roof Curbs
65
Time Guard
66
Hinged Access Panels
66
Advertisement
Bryant 581J Installation Instructions Manual (40 pages)
SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNIT SIZES 07, 08, 09 & 12 with PURON (R--410A) REFIRGERANT
Brand:
Bryant
| Category:
Air Conditioner
| Size: 6 MB
Table of Contents
Table of Contents
1
The Installation
2
Safety Considerations
2
Electrical Shock Hazard
2
Cut Hazard
2
Installation
7
Jobsite Survey
7
Step 1 - - Plan for Unit Location
7
Roof Mount
7
Step 2 - Plan for Sequence of Unit Installation
8
Curb- - Mount Installation
8
Pad- - Mount Installation
8
Frame- - Mount Installation
8
Step 3 - Inspect Unit
8
Step 4 - Provide Unit Support
8
Roof Curb Mount
8
Slab Mount (Horizontal Units Only)
8
Alternate Unit Support (in Lieu of Curb or Slab Mount)
8
Step 5 - Field Fabricate Ductwork
11
Step 6 - Rig and Place Unit
11
Positioning on Curb
12
Step 7 - - Convert to Horizontal & Connect Ductwork
12
Step 8 - Install Outside Air Hood
12
Economizer and Two Position Damper Hood Package Removal and Setup - Factory Option
12
Economizer Hood and Two- - Position Hood
13
Step 9 - Install Flue Hood
13
Step 10 - Install Gas Piping
13
Factory- - Option Thru- - Base Connections (Gas Connections)
14
Fire or Explosion Hazard
16
Step 11 - Install External Condensate Trap and Line
16
Step 12 - Make Electrical Connections
17
Field Power Supply
17
Fire Hazard
17
Units with Factory- - Installed Disconnect
17
Units Without Factory- - Installed Disconnect
17
All Units
17
Convenience Outlets
18
Installing Weatherproof Cover
18
Factory- - Option Thru- - Base Connections (Electrical Connections)
19
Units Without Thru- - Base Connections
19
Field Control Wiring
19
Thermostat
19
Unit Without Thru- - Base Connection Kit
20
Heat Anticipator Settings
20
Perfect Humidityt Control Connections
21
Perfect Humidity - - Space RH Controller
21
RTU Open Control System
23
Supply Air Temperature (SAT) Sensor
26
Outdoor Air Temperature (OAT) Sensor
26
Configurable Inputs
26
Economi$Er2
27
Field Connections
27
Space Temperature (SPT) Sensors
27
Indoor Air Quality (CO 2 ) Sensor
28
Outdoor Air Quality Sensor
28
Cover Removed
29
Smoke Detector/Fire Shutdown (FSD)
29
Side View
29
Space Humidity Sensor or Humidistat
29
Connecting Discrete Inputs
30
Filter Status
30
Communication Wiring - - Protocols
31
General
31
Local Access
32
RTU Open Troubleshooting
32
Outdoor Air Enthalpy Control
33
Differential Enthalpy Control
33
Return Air Enthalpy Sensor
34
Smoke Detectors
34
System
34
Controller
34
Sensor Module
34
Smoke Detector Locations
35
Supply Air
35
Return Air Without Economizer
35
Return Air with Economizer
35
Step 13 - - Adjust Factory- - Installed Options
40
Step 14 - - Install Accessories
40
Bryant 581J Installation, Start-Up And Service Instructions Manual (64 pages)
Variable Frequency Drive (VFD) Factory-Installed Option 2-Speed Motor Control for 2-Stage Cooling Rooftop Units
Brand:
Bryant
| Category:
Air Conditioner
| Size: 12 MB
Table of Contents
Table of Contents
1
Safety Considerations
1
General
2
2-Speed Indoor Fan Motor Indoor Fan Speed System
2
Identifying Factory Option
2
Unit Installation with 2-Speed Indoor Fan Motor Option
2
Pre-Start Check, 2-Speed Indoor Fan Motor Option
5
Start-Up, 2-Speed Indoor
16
Fan Motor Option
16
Compressor Rotation
16
Indoor Fan Motor
16
Cooling with 2-Speed Indoor Fan Motor
16
Operating Sequences, 2-Speed Indoor Fan Motor Option
16
Cooling (FAN Switch in AUTO)
16
Heating
17
Operating Fan for Test and Balance
17
Service
18
2-Speed Indoor Fan Motor Option Components
18
Fan Speed Relay Board
18
Configuration Jumpers
18
Variable Frequency Drive
18
Central Terminal Board Jumpers (548J/549J/551J/558J/580J/581J Series Only)
20
VFD Fuses
21
Control and Power Wiring Diagrams
22
Vfd Alarms and Faults Troubleshooting
29
Alarms
29
Faults
29
Vfd Maintenance
30
Heat Sink Cleaning
30
Fan Replacement
31
Bypass the VFD
33
Vfd Parameters
34
Vfd Remote Keypad
45
ACH550/ACS320 Operation with Remote Keypad
45
ACH550/ACS320 VFD Modes
45
ACH550/ACS320 VFD Diagnostics
47
Correcting Faults
47
History
47
Reset after Using Start-Up Assistant
50
ACH580 Operation with Remote Keypad
51
ACH580 VFD Modes
52
ACH580 VFD Diagnostics
54
All Ach580, Ach550 and Acs320 Keypads
57
Control Panel Cleaning
57
Battery Replacement
57
VFD Remote Keypad Parameters
57
Advertisement
Bryant 581J Installation Instructions Manual (24 pages)
3 to 12.5 Tons (48/50LC 14 Not Included) Accessory Ultra Low Leak Vertical EconoMiser X
Brand:
Bryant
| Category:
Air Conditioner
| Size: 2 MB
Table of Contents
Table of Contents
1
Safety Considerations
1
General
2
Accessories List
3
Compliance
3
Installation
4
Instructions for 48/50LC 07-12 Units Only
9
Installing Optional HH57AC081 Single Outside Air
13
Enthalpy Sensor
13
Installing Differential Return Air Sensor
14
California's Title 24 High Temperature Limit
14
Settings
14
Demand Controlled Ventilation (DCV)
14
Remote (Downstairs) Monitoring of Controller's Fault Detection and Diagnostics
15
General W7220 Controller and Sensor Information
16
W7220 Economizer
16
User Interface
16
Keypad
16
Using the Keypad with Menus
16
Using the Keypad with Settings and Parameters
16
Menu Structure
16
Programming W7220 Controller
16
Setpoints
16
System Setup
17
Checkout Tests
21
W7220 Economizer Module Wiring
22
Time-Out and Screen Saver
22
Start-Up and Operation
22
Cooling, Unit with Economi$Er® X
22
Heating with Economi$Er® X
22
Troubleshooting
24
Power Loss (Outage or Brownout)
24
Alarms
24
Clearing Alarms
24
Bryant 581J Manual (25 pages)
Rooftop Units 3 to 27.5 Nominal Tons
Brand:
Bryant
| Category:
Air Conditioner
| Size: 1 MB
Table of Contents
Electro- -Mechanical Controls
3
Safety Considerations
6
Electrical Shock Hazard
6
Cut Hazard
6
Specifications
8
Before Installation
8
Installation and Setup
9
Economizer Module Wiring Details
9
W7220 Economizer Module Wiring
9
CO 2 Sensor Wiring
10
Interface Overview
10
Menu Structure
11
Setup and Configuration
11
Sequence of Operation
17
Enthalpy Settings
21
Two- - Speed Fan Operation
21
Initial Menu Display
22
Troubleshooting
23
Clearing Alarms
23
Advertisement
Related Products
Bryant PREFERRED 581J*04A Series
Bryant PREFERRED 581J*05A Series
Bryant PREFERRED 581J*06A Series
Bryant PREFERRED 581J*07A Series
Bryant PREFERRED 581J*08D Series
Bryant PREFERRED 581J*09D Series
Bryant 581J series
Bryant 581Jx14 series
Bryant 581J 04 Series
Bryant 581J 06 Series
Bryant Categories
Air Conditioner
Furnace
Heat Pump
Thermostat
Fan
More Bryant Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL