Switch port information
Name, Identifier, and Syntax
snSwIfInfoSpeed
brcdIp.1.1.3.3.5.1.7
Syntax: Integer
snSwIfInfoMediaType
brcdIp.1.1.3.3.5.1.8
Syntax: Integer
snSwIfInfoConnectorType
brcdIp.1.1.3.3.5.1.9
Syntax: Integer
snSwIfStpPortEnable
brcdIp.1.1.3.3.5.1.15
Syntax: Integer
snSwIfInfoAutoNegotiate
brcdIp.1.1.3.3.5.1.19
Syntax: Integer
snSwIfInfoFlowControl
brcdIp.1.1.3.3.5.1.20
Syntax: Integer
snSwIfInfoGigType
brcdIp.1.1.3.3.5.1.21
Syntax: Integer
snSwIfFastSpanPortEnable
brcdIp.1.1.3.3.5.1.22
Syntax: Integer
48
Access
Description
Read-write
Indicates the speed configuration for a port:
s10M(2) – 10Mbits per second.
s100M(3) – 100Mbits per second.
The read-back hardware status are the following:
s10M(2) – 10Mbits per second.
s100M(3) – 100Mbits per second.
s1G(4) – 1Gbits per second.
The port media type (expansion or regular) and port link type
(trunk or feeder) determine whether this object can be written
and the valid values for this object.
Note that "writing" this variable writes the forced-mode
configuration, which is used when autonegotiation is disabled,
and has nothing to do with the current operation mode when
autonegotiation is enabled.
Read only
Shows the media type for the port:
other(1) – other or unknown media.
m100BaseTX(2) – 100Mbits per second copper.
m100BaseFX(3) – 100Mbits per second fiber.
m1000BaseTX(7) – 1Gbits per second copper.
Read only
Shows the type of connector that the port offers:
other(1) – Other or unknown connector
copper(2) – Copper connector
fiber(3) – Fiber connector
This describes the physical connector type
Read-write
Indicates if STP is enabled for the port:
disabled(0)
enabled(1)
Refer to the document IEEE 802.1D-1990: Section 4.5.5.2,
dot1dStpPortEnable.
Read-write
Applies only to Gigabit Ethernet ports.
Indicates if auto-negotiation mode is enabled on the port.
disable(0) – The port will be placed in non-negotiation mode.
enable(1) – The port will start auto-negotiation indefinitely
until it succeeds.
Default: enable(1)
Read-write
Indicates if port flow control is enabled:
disable(0)
enable(1)
Default: enabled(1)
Read only
Applies only to Gigabit Ethernet ports.
Shows the media type for the port:
m1000BaseSX(0) – 1-Gbps fiber, with a short wavelength
transceiver
m1000BaseLX(1) – 1-Gbps fiber, with a long wavelength
transceiver (3km)
m1000BaseTX(5) – 1-Gbps copper (100meter).
notApplicable(255) – a non-gigabit port.
Read-write
Indicates if fast span is enabled on the port.
disable(0)
enable(1)