Advanced Entry Calibration (continued)
Step
Operator Action
16 Press the
Using the
key, set the
'Paper' level to the value
determined in the previous
step. Press the
to set the entry (indicated
by the '*') and advance the
menu.
Repeat for the 'Gap' (or
'Mark') and 'Empty' levels.
17 After all entries have been
made, press the
key to back out of the menu
and then press the
key to save the settings and
return to the Ready Mode.
þ Note: If the Advanced Entry Calibration fails, try the following procedure.
Re-enter Media Settings / Calibration / Advanced Entry / Sensor Gain
and lower the selected Gain Setting number by one (to make the
sensor less sensitive). Select the new Gain Setting, save the changes,
exit the menu, and then test your media. Repeat the procedure until a
usable media setting is obtained.
70
Displayed Message
key.
or the
key
Or, for reflective media:
The selection
will flash and
the display
â
heading will
change to
indicate the
â
item for entry.
â
â
From 'Ready',
press the FEED
key to advance
to the next label
TOF.