4.1.6 Communications

SERIAL PORT A
BAUD RATE
38400
28800
19200
²9600
4800
2400
1200
PROTOCOL
²BOTH
SOFTWARE
HARDWARE
NONE
PARITY
²NONE
ODD
EVEN
DATA BITS
7
²8
STOP BITS
²1
2
SERIAL PORT B
PARALLEL PORT A
PORT DIRECTION
²UNI-DIRECTIONAL
BI-DIRECTIONAL
Controls the communications settings for
Serial Port A.
Determines the serial communication rate.
38400 bits per second
28800 bits per second
19200 bits per second
9600 bits per second
4800 bits per second
2400 bits per second
1200 bits per second
Sets the data flow control (handshaking)
method.
Uses both handshaking methods.
XON/XOFF
CTS/DTR
No flow control is used.
Sets Word parity
No parity
Odd parity
Even parity
Sets Word length
Seven bit Word length
Eight bit Word length
Sets the number of stop bits
One stop bit
Two stop bits
Same as Serial Port A, for an optional
connection. If not present, this displays
'NOT INSTALLED' when accessed.
Controls the communications settings for
Parallel Port A.
Determines if messages are sent from the
printer to the host via the parallel port.
One-way printer communication.
Enables IEEE 1284 back-channel operation.