Default
No description is associated with the configuration context.
Parameters
description-string — The description character string. Allowed values are any string up to 80 charac-
shutdown
Syntax
[no] shutdown
Context
config>cflowd
config>cflowd>collector
Description
This command administratively disables an entity. When disabled, an entity does not change, reset, or
remove any configuration settings or statistics.
The operational state of the entity is disabled as well as the operational state of any entities contained
within. Many objects must be shut down before they may be deleted.
The no form of this command administratively enables an entity.
Unlike other commands and parameters where the default state is not indicated in the configuration
file. The shutdown and no shutdown states are always indicated in system generated configuration
files.
inactive-timeout
Syntax
inactive-timeout seconds
no inactive-timeout
Context
config>cflowd
Description
This command specifies the amount of time, in seconds, that must elapse without a packet matching a
flow in order for the flow to be considered inactive.
The no form of this command resets the inactive timeout back to the default of 15 seconds.
Note: Existing flows will not inherit the new inactive-timeout value if this parameter is changed
while cflowd is active. The inactive-timeout value for a flow is set when the flow is first created in the
active cache table and does not change dynamically.
Default
15
Parameters
seconds — Specifies the amount of time, in seconds, that must elapse without a packet matching a
7750 SR OS Router Configuration Guide
ters long composed of printable, 7-bit ASCII characters. If the string contains special characters
(#, $, spaces, etc.), the entire string must be enclosed within double quotes.
flow in order for the flow to be considered inactive.
Values
10 — 600