16. Soft Switch Set (bizhub 160f/bizhub 161f only)
16.8.4

SOFT SWITCH: #04

Bit
Designation
No.
8
Reserved
7
Reserved
6
Reserved
5
Reserved
4
Visible alarm
for RTN signal
3
Audible alarm
for RTN signal
2
Reserved
1
Polarity change
detection
• Bit 3: The alarm lasts for 3 seconds after a negative signal is detected in G3 mode.
• Bit 4: The display message will stay put on the LCD for 3 seconds or until next incoming
T30 signal.
186
Function
Reserved
Reserved
Reserved
Reserved
0: No
1: Yes - display message while sending / receiving
RTN signal (RTN= Return To Negative).
0: No
1: Yes - alarm for sending or receiving RTN signal.
Reserved
0: Not to detect phase reverse during dialing & calling
1: Detect line phase reverse during dialing & calling