2.2.1.5

Timer Minimum Measurement Unit

The timer minimum measurement unit affects the sequencer, the emulation timer and the
performance measurement timer.

■ Setting Timer Minimum Measurement Unit

Choose either 1 μs or 100 ns as the timer minimum measurement unit for the emulator for measuring time.
The minimum measurement unit for the following timers is changed depending on this setup.
• Timer values of sequencer (timer conditions at each level)
• Emulation timer
• Performance measurement timer
Table 2.2-3 shows the maximum measurement time length of each timer when 1 μs or 100 ns is selected as
the minimum measurement unit.
When the minimum measurement unit is changed, the measurement values of each timer are cleared as well.
The default setting is 1 μs.
Table 2.2-3 Maximum Measurement Time Length of Each Timer
Sequencer timer
Emulation timer
Performance measurement timer
Use the following commands to control timers.
SET TIMERSCALE :
SHOW TIMERSCALE :
[Example]
>SET TIMERSCALE/100N
>SHOW TIMERSCALE
Timer scale : 100ns
>
1 μs selected
About 16 seconds
About 70 minutes
About 70 minutes
Sets minimum measurement unit for timers
Displays status of minimum measurement unit setting for timers
CHAPTER 2 DEPENDENCE FUNCTIONS
100 ns selected
About 1.6 seconds
About 7 minutes
About 7 minutes