CHAPTER 2 DEPENDENCE FUNCTIONS
2.2.6.1

Operation in Normal Mode

As shown in the figure below, the event trigger set in the normal mode performs input to
the sequencer. In the sequencer, either branching to any level, or terminating the
sequencer, can be specified as an operation at event trigger occurrence. This enables
debugging (breaks, limiting trace, measuring time) while monitoring program flow.
■ Operation in Normal Mode
The termination of sequencer triggers the delay counter. When the delay counter reaches the specified count,
sampling for the single trace terminates. A break normally occurs at this point, but if necessary, the program
can be allowed to run on without a break.
SET SEQUENCE/DISABLE TRACE
SHOW SEQUENCE level
SET EVENT
CANCEL EVENT
Enable
Select event number causing
Events
trigger at each level, set
pass count value.
Disable
SET
SEQUENCE/EVENT
DISABLE EVENT
ENABLE EVENT
SHOW EVENT
90
Figure 2.2-3 Operation in Normal Mode
SET SEQUENCE/NO TRACE
SET SEQUENCE/ENABLE TRACE
CANCEL
SEQUENCE/TIMER
SET
SEQUENCE/TIMER
CANCEL
SEQUENCE/EVENT
DISABLE TRACE
ENABLE TRACE
SHOW TRACE/DATA
CLEAR TRACE
SEARCH TRACE
When each condition at each level met
Timer setup
for each
condition
When condition met
Sequencer
Timer latch
SHOW SEQUENCE/ALL
SHOW DELAY
SHOW TRACE/STATUS
Enable/Disable
Buffer-full break
control
control
Single trace measurement
Enable/Disable
Measurement ends
control
When count ends
Delay
counter
Instructing MCU to
When count ends
suspend operation
SET DELAY