Troubleshooting Chart

Symptom
Cannot connect
using Telnet, Web
browser, or SNMP
software
Can't access the
on-board
configuration
program via a serial
port connection
Forgot or lost the
password
T
ROUBLESHOOTING
Troubleshooting Chart
Action
Be sure to have configured the agent with a valid IP
address, subnet mask and default gateway.
Check that you have a valid network connection to
the switch and that the port you are using has not
been disabled.
Check network cabling between the management
station and the switch.
If you cannot connect using Telnet, you may have
exceeded the maximum number of concurrent
Telnet sessions permitted. Try connecting again at a
later time.
Be sure to have set the terminal emulator program
to VT100 compatible, 8 data bits, 1 stop bit, no
parity and 19200 bps.
If the switch is configured for Auto (baud rate
detection), the terminal emulator program must be
set at 2400~19200 baud, 8 data bits, 1 stop bit, no
parity, and flow control set to none. Also, you must
first press the Enter key once to set the data rate and
initialize the connection.
Check that the null-modem serial cable conforms to
the pin-out connections provided in Appendix B.
Contact SMC Technical Support for help.