Activity Led; Event Triggering - VBrick Systems VB6000 Series Getting Started Manual

Network video appliances
Hide thumbs Also See for VB6000 Series:
Table of Contents

Advertisement

Open or Closed. The Relay port specification is dry contact, 75mOhms, 2A @ 30VDC, 0.5A
@ 125VAC. The mini stereo plug should be wired as shown in the following diagram.

Activity LED

The
LED behaves differently depending on the Part Number of the Main Board. On
Activity
appliances where the Part Number ends in 2, the
Ethernet activity. On appliances where the Part Number ends in 3 or higher, the appliance
has a tri-color LED that shows different status activities as shown in the table. (To determine
part number, open IWS and go to
The tri-color
Activity
Table 21. Tri-Color Activity LED
Clear
Green
Red
Orange

Event Triggering

The VB6000 event triggering feature lets you use an external switch to control the function
of the VBrick. This section provides some examples of how to use this feature. In all the
examples, a high event is triggered when the switch is closed and a low event is triggered
when the switch is opened. The event trigger inputs on the VBrick recognize a high voltage
anywhere above +8 volts DC with an upper limit of +12 volts. A low voltage is anything at or
below 0 volts DC with a lower limit of -12 volts. The event can also be configured to run a
script on Pin 7 or Pin 8 depending on how the connection is configured. See "Configuration:
Script Management" in the VBrick MPEG-2/4 Appliance Admin Guide for configuration
details; see RS-232/422/485 COM Port Pinouts for pinout details.
Note You cannot execute a script either with the IR Remote Control or using an event
trigger if IWS is currently running in
IWS, it automatically exits
Example 1
Connect an external power supply (+8V to +12V) and a switch directly to the ground pin and
an event pin of the COM1 port on the VBrick.
72
Status: User Information > Main Board > Part Number
LED blinks at one-second intervals in the following sequential order:
Off; no activity
Ethernet activity
If there is TX or RX activity on COM1
If there is TX or RX activity on COM2
mode and terminates the active editing session.
Edit
LED blinks green when there is
Activity
mode. If you run a script directly from
Edit
© 2008 VBrick Systems, Inc.
.)