Command Line Interface
Topics in this chapter

Connection Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49

MIB-Based Command Line Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Menu-Based Command Line Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Connection Modes
Telnet (as well as FTP, IWS, and SNMP) can be disabled for security purposes. If you cannot
login to the appliance, check that Telnet is enabled. Go to Configuration: System > Security
> External Telnet Server.

Connecting with HyperTerminal

VBrick's command line interface is simple, intuitive, and menu driven. To manage an
appliance with HyperTerminal, connect the included cable (which provides a standard 9-pin
serial connection) from the serial port on the computer to the VBrick's COM2 RJ-45
connector. To access the VBrick using HyperTerminal go to
Accessories > Communication > HyperTerminal
Communications Port (usually COM1).
Upon connection to a terminal (9600 bps Async, 8-bit, no parity, flow control = none), a
prompt for login (username) and password will be displayed. (Ethernet VBricks also support
Telnet. The display is identical to that of a local terminal.) Login and password are case
sensitive (admin). Once logged in, the main menu will appear by typing a question mark (?) at
the VBrick> prompt.
VBrick Appliance Getting Started Guide
Chapter 7
Start > Programs >
. Connect through your computer's
49

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vb4000 seriesVb5000 series

Table of Contents