Converting The Pressure Regulator & Maintop Burners For L - Whirlpool SF372BEE W/N Service Manual

Freestanding self-clean gas range
Hide thumbs Also See for SF372BEE W/N:
Table of Contents

Advertisement

CONVERTING THE PRESSURE REGULATOR &
MAINTOP BURNERS FOR L.P. GAS
THE PRESSURE REGULATOR
WARNING
Personal Injury Hazard
Do not operate the burners of this range when
using L.P. (bottled) gas before converting the
pressure regulator, burner orifices, and oven
pilot adjustment screw (if applicable), for L.P.
gas usage.
Failure to follow these instructions could result
in high flames and toxic fumes, causing serious
injury.
Fire Hazard
Shut off the gas supply line valve.
Make all conversions before turning gas supply
valve back on.
Failure to follow these instructions could result
in explosion, fire, or other injury.
Conversions to the pressure regulator and burner
orifices for L.P. gas usage must be done by a
qualified service technician. Do not remove the
regulator to convert it.
To convert the regulator from natural to L.P. gas,
use the following procedure:
1.
Remove the storage drawer from the range.
2.
Remove the plastic cover from the pressure
regulator.
3.
Use a wrench, and turn the cap marked "N" on
the front of the pressure regulator counter-
clockwise, and remove it. NOTE: Do not dis-
turb the spring under the cap.
4.
Turn the cap over so that the letters L.P. are
visible and reinstall it into the regulator.
5.
Reinstall the plastic cover on the pressure
regulator.
Pressure Regulator
Pressure Regulator
Natural Gas
1-10
Natural Gas
L.P. Gas
cap
washer
L.P. Gas

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents