Printer requirements and specifications
WYE (or Star)
configurations–
50 Hz
Printer power
outlet/cord voltage
configurations–50
Hz
6-4
For the 50 Hz WYE configuration, measure the WYE or Star
connection voltages at the power source.
Table 6-3. Printer (50 Hz) WYE (Star) 415 voltage
Service outlet
Measurement
configuration
of wiring
5 Wire 415 V
Line 1 to line 2
5 Wire 415 V
Line 2 to line 3
5 Wire 415 V
Line 1 to Line 3
5 Wire 415 V
Line 1 to neutral 240 V RMS
5 Wire 415 V
Line 2 to neutral 240 V RMS
5 Wire 415 V
Line 3 to neutral 240 V RMS
The following lists the 50 Hz WYE/Star printer outlet information
for 380 and 400 volts.
Table 6-4. Printer (50 Hz) WYE (Star) 380 and 400 voltage
Service outlet
Measurement
configuration
of wiring
5 Wire 380 V
Line 1 to line 2
5 Wire 380 V
Line 2 to line 3
5 Wire 380 V
Line 1 to Line 3
5 Wire 380 V
Line 1 to neutral 220 V RMS
5 Wire 380 V
Line 2 to neutral 220 V RMS
5 Wire 380 V
Line 3 to neutral 220 V RMS
5 Wire 400 V
Line 1 to line 2
5 Wire 400 V
Line 2 to line 3
5 Wire 400 V
Line 1 to Line 3
5 Wire 400 V
Line 1 to neutral 230 V RMS
5 Wire 400 V
Line 2 to neutral 230 V RMS
5 Wire 400 V
Line 3 to neutral 230 V RMS
For 50 Hz systems outlet/power cord configurations, consult your
local service representative to determine the type of plug and
receptacle to use.
Nominal
Range
415 V RMS
374-457 V RMS
415 V RMS
374-457 V RMS
415 V RMS
374-457 V RMS
216-264 V RMS
216-264 V RMS
216-264 V RMS
Nominal
Range
380 V RMS
342-419 V RMS
380 V RMS
342-419 V RMS
380 V RMS
342-419 V RMS
198-242 V RMS
198-242 V RMS
198-242 V RMS
400 V RMS
358-438 V RMS
400 V RMS
358-438 V RMS
400 V RMS
358-438 V RMS
207-253 V RMS
207-253 V RMS
207-253 V RMS