6. Useful Functions

6.1 Drive the Digital Output

Note: This request requires Viewer privileges.
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/setdo.cgi?do1=<state>[&do2=<state>]
[&do3=<state>][&do4=<state>][&return=<return page>]
Where state is 0 or 1; "0" means inactive or normal state, while "1" means active or triggered state.
PARAMETER VALUE
DESCRIPTION
do<num> 0, 1
0 – Inactive, normal state
1 – Active, triggered state
return
<return
Redirect to the page <return page> after the parameter is assigned. The <return
page>
page> can be a full URL path or relative path according to the current path. If you
omit this parameter, it will redirect to an empty page.
Example: Drive the digital output 1 to triggered state and redirect to an empty page.
http://myserver/cgi-bin/dido/setdo.cgi?do1=1

6.2 Query Status of the Digital Input

Note: This request requires Viewer privileges
Method: GET/POST
Syntax:
http://<servername>/cgi-bin/dido/getdi.cgi?[di0][&di1][&di2][&di3]
If no parameter is specified, all of the digital input statuses will be returned.
Return:
HTTP/1.0 200 OK\r\n
Content-Type: text/plain\r\n
Content-Length: <length>\r\n
\r\n
[di0=<state>]\r\n
[di1=<state>]\r\n
VIVOTEK