READY 00:00
NORMAL MODE
USER SETTINGS
INSTALLER MODE
ENTER CODE
note
[inst. code] (see
)
1. NEW INSTL CODE
2. ENROLLING
3. DEFINE ZONES
4. DEFINE PANEL
5. DEFINE COMM.
<OK> TO EXIT
Note
For Control Panel that has
installer code & master
installer code, the following
functions are available only if
the MASTER INSTALLER
code is entered:
05: 1ST CNTR TEL
06: 1ST ACCOUNT #
07: 2ND CNTR TEL
08: 2ND ACCOUNT #
09: REPORT FORMAT
10: 4/2 PLS RATE
11: REPORT
CNTR
12: RPRT CNF ALRM
13: SEND 2WV CODE
14: VOICE
C.S.
15: RINGBACK TIME
16: DIAL ATTEMPTS
27: MAST. DL CODE
Note
The currently saved options
are displayed with dark box
at the right side of the display.
To review the opt ions,
repeatedly click
or
until the desired option
is displayed, then click OK (a
dark box will be displayed at
the right side).
21: TEL ACKNWLDGE
single ack
all ack
26:REMOTE ACCESS
rem. access on
rem. access off
31: UPLOAD OPTION
when system OFF
any time
Not applicable
in the USA
Applicable for USA only
38:AMBIENT LEVEL
high
low
D-300885
01: AUTOTEST TIME
Test time 12:00 P
(Enter test time)
(See note)
05: 1ST CNTR TEL
xxxxxxxxxxxxxxxx
(Enter Tel. No.)
(See note)
09:REPORT FORMAT
contact ID
SIA
4/2 1900/1400
4/2 1800/2300
Scancom
(See appendix - code list)
(See note)
13: SEND 2WV CODE
time out 10 s
send
time out 45 s
don't send
time out 60 s
time out 90 s
time out 2 m
ring back
disable
17: SET PRVT TEL#
1st private tel#
2nd private tel#
3rd private tel#
4th private tel#
xxxxxxxxxxxxxxxx
(Enter Tel. No.)
22: PAGER TEL #
xxxxxxxxxxxxxxxx
(Enter Tel. No.)
(See note)
27: MAST. DL CODE
downl. code AAAA
xxxx
(Enter 4-digit code)
("0000" is not valid)
32: DIAL METHOD
tone (dtmf)
pulse
Applicable for UK only
39: REP. 24h ZONES
both original
audibl as panic
silent as panic
both as panic
Figure 4.5 - DEFINE COMM Flow Chart
02:AUTOTST CYCLE
test every 1d
test every 5d
test every 7d
test every 14d
test every 30d
test every 5 h
test OFF
(See note)
06: 1ST ACCOUNT #
xxxxxx
(Enter account No.)
(See note)
10: 4/2 PLS RATE
11: REPORT
10 pps
all - o/c * backup
20 pps
all
33 pps
all - o/c * all - o/c
all - o/c * o/c
40 pps
all (-alrt) * alrt
alrm * all (-alrm)
disable report
all * backup
(See note)
15: RINGBACK TIME
14: VOICE
C.S.
1 minute
3 minutes
5 minutes
10 minutes
18: VOICE
PRVT
19: PRVT ATTEMPTS
enable two-way
1 attempt
disable two-way
2 attempts
3 attempts
4 attempts
23: PAGER PIN #
24: REPORT PAGER
all
xxxxxxxxxxxxxxxx
alarm +alert
all (-op/cl)
(Enter PIN No.)
trbl + op/cl
trbl
op/cl
disable report
28: INST. DL CODE
downl. code BBBB
xxxx
(Enter 4-digit code)
("0000" is not valid)
33: LINE FAIL REP
don't report
immediately
5 minutes
30 minutes
60 minutes
180 minutes
03:AREA CODE
04: OUT ACCESS No
xxxx
(Enter tel. area
code, up to 4-digit)
access code, 1-digit)
(See note)
07: 2ND CNTR TEL
08: 2ND ACCOUNT #
xxxxxxxxxxxxxxxx
(Enter Tel. No.)
(Enter account No.)
(See note)
12: RPRT CNF ALRM
CNTR
enable report
* all
disable report
enable + bypass
(See note)
16: DIAL ATTEMPTS
2 attempts
4 attempts
8 attempts
12 attempts
16 attempts
20: REPORT PRVT
all
all (-op/cl)
all (-alerts)
alarms
alerts
op/cl
disable report
25: RECENT CLOSE
recent cl. on
recent cl. off
30: ZONE RESTORE
report restore
don't report
34: UL/DL TEL #
35: SYS INACT REP
disable
xxxxxxxxxxxxxxxx
rep after 7d
(Enter Tel. No.)
rep after 14d
rep after 30d
rep after 90d
x
(Enter ext. tel. line
(See note)
xxxxxx
(See note)
(See note)
21