Action
L I G H T O N
L I G H T O N
R E A D Y
The lights controlled by X-10 unit No. 01 are switched on

4.3 Manual Switch-Off

You can switch appliances OFF as instructed below. This
example shows how to switch off the lights controlled by X-
10 unit No. 01.
Action
L I G H T O F F
L I G H T O F F
R E A D Y
The lights controlled by X-10 unit No. 01 are switched off

4.4 Light DIM/BRIGHT

Immediately after activating a light (see para. 4.2), you can
dim or brighten it as desired. For this purpose, enable the
DIM/BRIGHT function by pressing
several times (as desired) the
button.

4.5 Automatic ON/OFF Control

You can select two of four options:
By Timer ON
By timer OFF
5. READING ALARM MEMORY AND TROUBLE DATA

5.1 Reviewing Alarm/Tamper Memory

The PowerMax+ retains in its memory alarm and "tamper"
events that occurred during the last arming period.
Note: Alarms enter the memory only after expiry of the
"abort period" (see Appendix A). This means that if you
disarm the system immediately - before the abort period
expires - there will be no memory indication.
A. Alarm / Tamper Indications
When the memory contains at least one event and the
system is in the disarmed state, a flashing MEMORY
message will be displayed as exemplified:
R E A D Y
(alternating)
R E A D Y
or, if the system is not ready for arming -
N O T R E A D Y
(alternating)
N O T R E A D Y M E M O R Y
B. Investigating Alarm/Tamper Data
To review memory content, click the SHOW/OK button.
EXAMPLE 1: An alarm was triggered because the garage
door - zone No. 12 - opened but then re-closed. In
addition, the bedroom motion detector - zone No. 7 - sent
a "Tamper" message because its cover had been removed.
DE5467U
Resultant Display
1
H H : M M
Resultant Display
1
H H : M M
or
, then press
(DIM) or
(BRIGHT)
H H : M M
M E M O R Y
H H : M M
By sensor ON
Sound
The presently active options are shown with a dark box
( ) at the far right. To view the 2 other options click <9>.
A presently inactive option is shown without a dark box at
the far right. The dark box will appear if you click <OK>
while the option is displayed. The
"Happy Tune" - successful saving of a new option.
Action
If not satisfied -
Sound
If satisfied -
If not satisfied -
If satisfied -
Action
In response to additional clicking of <SHOW/OK> button,
the display show details of other events retained in memory
(if any), or reverts to its initial state (see A above).
EXAMPLE 2: An alarm was triggered because the garage
door - zone No. 12 - opened and was left open.
Action
By sensor OFF
represents the
Resultant Display
B Y T I M E R O N
(if this is the default)
B Y T I M E R O F F
B Y T I M E R O F F
B Y T I M E R O F F
B Y S E N S O R O N
(if this is the default)
B Y S E N S O R O F F
B Y S E N S O R O F F
B Y S E N S O R O F F
R E A D Y
H H : M M
Resultant Display
R E A D Y
H H : M M
Z 1 2 A L A R M E D
(alternating)
G A R A G E D O O R
Z 0 7 T A M P E R - O P E N
(alternating)
B E D R O O M
Resultant Display
N O T R E A D Y H H : M M
Z 1 2 A L A R M E D
(alternating)
G A R A G E D O O R
Z 1 2 O P E N
(alternating)
G A R A G E D O O R
Sound
Sound
Sound