Specification For The Pushrod Drives; Forces On The Building - Viessmann KOB PYROTEC Technical Manual

Grate combustion 390 to 1250 kw, fully automatic wood boiler, for the combustion of woodchips, pellets, shavings and mixed wood
Table of Contents

Advertisement

Design information
(cont.)
Max. permissible dumping height and length of the pushrods in S650
Trade name
Type
Part no.:
Dumping height with length:
12
10
8
6

Specification for the pushrod drives

Trade name
Type
Part no.:
Piston diameter
Piston rod diameter
Lift
Test pressure
Pressure force at 190 bar FZD
Tensile force at 190 bar FZZ
Length from centre of cylinder - piston boss

Forces on the building

In the case of pushrod drives for discharge push floors with several
pushrods, the hydraulic cylinders have pipes laid in opposite flow
directions, i.e. the first cylinder pulls, the second cylinder pushes, the
third cylinder pulls, etc. The cylinder with the lowest pressure drops
generally moves first into the end position, then the next one.
FG1 Maximum tensile force on the weld base of the bunker upwards
per metre length
FS
Total standard forces on the front panel (slot discharge)
PYROTEC
AS-2.50
AS-2.25
7387 992
7387 995
m
1.5
m
1.9
m
2.6
m
3.7
Individual stand-
mm
mm
mm
bar
kN
kN
mm
When all cylinders are in the end position, the oil pressure increases
up to the response pressure for the pressure diverter valve (set to 190
bar at the factory) and this switches to the opposite direction.
FR
Total standard forces on the back panel
FR1 Standard force of a pushrod on the back panel
FS1 Standard force of a pushrod on the front panel
Pushrod
AS-2.0
AS-1.75
7387 836
7387 956
1.8
2.0
2.4
2.3
2.6
3.1
3.0
3.5
4.2
4.3
4.9
6.1
Pushrod drive
Twin standard
ard
7387 978
7387 915
180
180
90
90
600
600
240
240
484
484
362
362
Type K
Type L
1080
1230
AS-1.5
7387 989
2.9
3.7
4.9
7.4
Heavy
Version
On request
220
110
800
240
722
542
-
1575
6
53