Centre Discharge - Viessmann KOB PYROTEC Technical Manual

Grate combustion 390 to 1250 kw, fully automatic wood boiler, for the combustion of woodchips, pellets, shavings and mixed wood
Table of Contents

Advertisement

Design information
(cont.)
10,29 mm
A
B
6,02 mm
0,89 mm
19,48 mm
9,50 mm
50
1230
27,72 mm
> 1750
C
E
C
FZZ
A
A
K
FZD
H
G
Required order data for the above example:
Position
Part no.
A
7387 978
B
7387 924
C
7387 952
D
7387 830
E
F
Corresp. to length
See pricelist
G
Corresp. to dimensions
See pricelist
H
7387 904
K
Corresponding boiler output
See pricelist

Centre discharge

The drawing below is a general arrangement and should not be used
for construction design. A project-related drawing must be produced
for construction design.
PYROTEC
a
b
600
95,02 mm
(4000 - 12000)
A - A
FS1
Quantity
Unit
2
pce
1
pce
2
pce
2
pce
2
pce
1
pce
1
pce
1
pce
Note
Use only KÖB original weld bases for the pushrod drive!
0,48 mm
50 - 150
F
D
D
FR1
Pushrod drive AS individual with hydraulic cylinder type L
Cover for push floor screw conveyor (optional)
Weld base, AS individual
Hydraulic compartment
Pushrod (incl. stop wedges)
Push floor screw conveyor
Version and drive, AQ standard
Hydraulic drive, ASH individual
A
6
Designation
Weld base, bunker
55